Honeywell TC682EL User Manual

Page 3

Advertising
background image

10

9

12

11

NOTE: When the temperature falls below freezing, the

batteries in the outdoor remote sensor may have

reduced voltage supply and a shorter effective range.

We recommend using lithium batteries at temperatures

of 32°F (0°C) and below.

BATTERY INSTALLATION

REMOTE SENSOR

NOTE: Install the batteries; select the channel and

temperature in °C or °F before mounting the remote

sensor.

Remove the screws from the battery compartment with

a small Phillips screwdriver.

• Set the channel. The switch is located in the battery

compartment. Channel 1 is typically selected if only

one remote sensor is being used.

• Install 2 “AA” size alkaline batteries (not included)

matching the polarities shown in the battery compartment.

• Replace the battery compartment door and secure the screws.

• Secure the remote sensor in the desired location.
MAIN UNIT

• Slide to the right the battery compartment door on the

back of the unit and remove it.

• Install 2 batteries (UM-3 or “AA” size 1.5V) matching

the polarity as shown in the battery compartment.

• Replace the battery compartment door.
LOW BATTERY WARNING

A low-battery indicator [ ] will appear next to the

indoor or remote data reading line of the main unit warning

that the corresponding batteries need replacement.

GETTING STARTED

DIGITAL WEATHER DISPLAY

After batteries are installed; remote sensor will transmit

temperature and humidity data at 45 second intervals.

The main unit may take up to two minutes to receive the

initial readings. Upon successful reception, remote

temperature and humidity will appear under the weather

forecast section of the main unit’s display (the default

remote channel is channel one). The main unit will

automatically update readings at 45-second intervals.

After communication between the main unit and

remote sensor has been established, secure the remote

sensor in the desired location.

If no signal is received from the remote sensor within two

minutes, dashes [- - -] will be displayed. Press and hold

the DOWN ( ) button on the main unit for two seconds

to initiate another signal search.
PLACEMENT OF THE UNITS

The main unit can be placed on any flat surface indoors.

The remote sensor can be placed indoors or outdoors, on

a flat surface or mounted on the wall.

PROGRAMMABLE TEMPERATURE ALARM

This product allows manual programming of a HIGH and

LOW temperature alarms for all three remote channels.

Once the actual remote temperature will reach the pre-set

high or low limits, the alarm will sound. The alarm can be

set for temperature readings between -58 °F and 158°F.
To program the temperature alarm for all remote channels,

• Press the TEMP ALARM button once to enter into the

Temperature Alarm Programming mode – the

abbreviation "OF" will be displayed on the remote

temperature line

• Press and hold TEMP ALARM button until the lower

temperature limit value (-58) will flash

• Set the desired lower temperature limit using

DOWN ( ) arrow button

• Press TEMP ALARM button once confirming the

lower temperature limit value

• Press and hold TEMP ALARM button until the HIGH

temperature limit value ( 158) will flash

• Set the desired higher temperature limit using

DOWN ( ) arrow button

• Press TEMP ALARM button once confirming the

higher temperature limit value

The unit is in a searching mode.

Temperature and humidity

readings are securely registered.

No signals detected.

- - -

The indoor temperature and humidity with the icon IN are

located below the remote temperature and humidity

information line.

NOTE: If the indoor or remote temperature or humidity

goes above or below operating range stated in specifications,

the main unit’s display ( weather station portion) will show

dashes "- - -" on the corresponding line.

AUTO-SCANNING

Press and hold the CHANNEL button for 2 seconds – the

icon " " will appear on the main unit weather display

above the COMFORT LEVEL indicator.

All three remote channels data will be displayed

one-by-one automatically with a 4 seconds delay in the

following sequence: Channel 1, Channel 2 and Channel 3.

To exit from scanning mode, press and hold the

CHANNEL button for 2 seconds, and the icon " " will

disappear, returning the main unit weather display to the

default display mode.

REMOTE AND INDOOR TEMPERATURE &

HUMIDITY

The remote temperature and humidity information line is

located right below the weather forecast line of the main

unit’s display.

The wave icon is located above the remote channel number

indicates the reception status from the corresponding

remote sensor.

There are three following types of the reception status

may be displayed: