Vent information and diagrams, A. vent guidelines, B. vent system configuration – Heatiator CB4842IR User Manual

Page 21

Advertising
background image

Heatilator • Caliber BV Series • 4040-262 • Rev M • 08/09

2

Minimum

clearances are

per vent

manufacturer's

specifications

Metal

plumber's strap

secured to

framing

Vent supports are per

vent manufacturer's

specifications

12 ft (3.66 m) min.

60 ft (18.29 m) max.

45°

Elbow

90°

Elbow

Offsets exceeding

45° adapt horizontal

limitations

Maximum

horizontal

30 ft (9.14 m)

Note: Maximum horizontal

distance is 50% of vertical

vent height.

Maximum horizontal run is 50% of

vertical. Horizontal run cannot be

more than 30 ft. (9.14 m).

Vent supports

are per vent

manufacturer’s

specifications.

Metal

Plumbers'

Strap

7

Vent Information and Diagrams

A. Vent Guidelines

WARNING! Fire Risk/Asphyxiation! This appliance re-

quires the specified pipe for operation. Incorrect pipe may

cause spillage, condensation and overheating.
These models require the 5 in. (27 mm) B-vent double

wall vent pipe.
• This system MUST terminate vertically.

• Follow pipe manufacturer’s installation guidelines when

installing the appliance.

B. Vent System Configuration

CAUTION! Risk of Fire! ALL vent configuration specifi-

cations MUST be followed.

This product is tested and listed

to these specifications. Appliance performance will suffer if

specifications are not followed.

Rise to Run Ratio = 2:
Maximum Total Horizontal Run = 0 Feet
Minimum Total Vertical Rise = 2 Feet
Maximum Total Vertical Rise = 60 Feet
Maximum Number of Elbows: Four 90º or Eight 45º

WARNING!

Fire Risk/Explosion/Asphyxiation!

DO NOT

connect this gas appliance to a chimney flue serving a

separate solid-fuel or gas burning appliance.
• Vent this appliance directly outside.

• Use separate vent system for this appliance.
May impair safe operation of this appliance or other

appliances connected to the flue.

WARNING! Risk of Fire or Explosion! Insulation and

other combustibles must not infringe on clearances.
• ALWAYS maintain specified clearances around venting

and firestop systems.

• Install firestops as specified.
Failure to keep insulation or other material away from vent

pipe may cause fire.

Figure 7.1 Vertical Termination Clearances

Figure 7.2 Maximum Horizontal Run

Figure 7.3 Maximum Horizontal Run