Installing vent pipe – Heatiator CB4842IR User Manual

Page 24

Advertising
background image

Heatilator • Caliber BV Series • 4040-262 • Rev M • 08/09

24

Tabs

10

Installing Vent Pipe

A. Assembly of Vent Sections

This B-Vent appliance requires 5 in. B-vent double-wall

pipe. Follow the pipe manufacturer’s installation guide-

lines when installing the unit. This will ensure proper

operation and prevent safety hazards.

WARNING! Risk of Fire/Exhaust Fumes! Assemble

pipe sections per B-vent manufacturer’s instructions. Use

support tabs for screws. Pipe may separate if not prop-

erly joined.

B. Attach Vent to Firebox

Three tabs extend from appliance collar shield. Attach

tabs to first section of B-vent pipe using self-tapping 1/4 in.

screws supplied with appliance. See Figure 0..

Figure 10.1 Attach Vent to Firebox

C. Secure Vent Sections

Secure vent sections with vent supports following B-vent

manufacturer’s instructions.

WARNING! Risk of Fire or Explosion! Use vent run

supports per vent manufacturer’s installation instructions.
• Connect vent sections per vent manufacturer’s

installation instructions.

• Maintain all clearances to combustibles. Maintain

specified slope (if required).

• Improper support may allow vent to sag or separate.

D. Install Attic Insulation Shield

WARNING! Fire Risk. DO NOT allow loose materials or

insulation to touch vent. Hearth & Home Technologies Inc.

requires the use of an attic shield.
The National Fuel Gas Code ANSI Z22. and NFPA 54

requires an attic shield constructed of 26 gauge minimum

metal that extends at least 2 in. (5 mm) above insulation.
Attic shields must meet vent manufacturer’s specified

clearance and be secured in place per vent manufactur-

er’s instructions.

Advertising
This manual is related to the following products: