Heatilator • Caliber BV Series • 4040-262 • Rev M • 08/09

25

A. Fuel Conversion

• Make sure the appliance is compatible with available

gas types.

• Conversions must be made by a qualified service

technician using Hearth & Home Technologies specified

and approved parts.

C. Gas Connection

• Refer to Reference Section 6.A. for location of gas line

access in appliance.

• Gas line may be run through knockout(s) provided on

either side or the bottom of the appliance.

• The gap between supply piping and gas access hole

may be caulked with high temperature caulk or stuffed

with non-combustible, unfaced insulation to prevent cold

air infiltration.

• Ensure that gas line does not come in contact with outer

wrap of the appliance. Follow local codes.

• Pipe incoming gas line into valve compartment.

• Connect incoming gas line to the /2 in. ( mm)

connection on manual shutoff valve.

WARNING! Risk of Fire or Explosion! Support control

when attaching pipe to prevent bending gas line.
• A small amount of air will be in the gas supply lines.
WARNING! Risk of Fire or Explosion! Gas build-up dur-

ing line purge could ignite.
• Purge should be performed by qualified service

technician.

• Ensure adequate ventilation.

• Ensure there are no ignition sources such as sparks or

open flames.

Light the appliance. It will take a short time for air to purge

from lines. When purging is complete the appliance will

light and operate normally.

WARNING! Risk of Fire, Explosion or Asphyxiation!

Check all fittings and connections with a non-corrosive

commercially available leak-check solution.

DO NOT use

open flame. Fittings and connections could have loos-

ened during shipping and handling.

WARNING! Risk of Fire! DO NOT change valve settings.

This valve has been preset at the factory.

WARNING! Risk of Fire or Explosion! High pressure

will damage valve. Low pressure may cause explosion.
• Verify inlet pressures. Verify minimum pressures when

other household gas appliances are operating.

• Install regulator upstream of valve if line pressure is

greater than /2 psig.

11

Gas Information

Gas Pressure

Natural Gas

Propane

Minimum inlet pressure

5.0 in. w.c.

.0 in. w.c.

Maximum inlet pressure

0.0 in. w.c.

.0 in. w.c.

Manifold pressure

.5 in. w.c.

0.0 in. w.c.

Note: Have the gas supply line installed in accordance with local

codes, if any. If not, follow ANSI 22.. Installation should be done

by a qualified installer approved and/or licensed as required by

the locality. (In the Commonwealth of Massachusetts installation

must be performed by a licensed plumber or gas fitter).
Note: A listed (and Commonwealth of Massachusetts approved)

1/2 in. (13 mm) T-handle manual shut-off valve and flexible gas

connector are connected to the /2 in. ( mm) control valve

inlet.

• If substituting for these components, please consult

local codes for compliance.

D. High Altitude Installations

NOTICE: If the heating value of the gas has been reduced,

these rules do not apply. Check with your local gas utility or

authorities having jurisdiction.
When installing above 2000 feet elevation:
• In the USA: Reduce burner orifice 4% for each 1000 feet

above 2000 feet.

• In CANADA: Reduce burner orifice 10% for elevations

between 2000 feet and 4500 feet. Above 4500 feet,

consult local gas utility.

Fire Risk.
Explosion Hazard.
High pressure will damage valve.
• Disconnect gas supply piping BEFORE

pressure testing gas line at test pressures

above /2 psig.

• Close the manual shutoff valve BEFORE

pressure testing gas line at test pressures

equal to or less than /2 psig.

WARNING

B. Gas Pressure

• Optimum appliance performance requires proper input

pressures.

• Gas line sizing requirements will be determined in ANSI

Z22. National Fuel Gas Code in the USA and CAN/

CGA B49 in Canada.

• Pressure requirements are: