A. intellifire ignition system (continued) – Heatiator CB4842IR User Manual

Page 33

Advertising
background image

Heatilator • Caliber BV Series • 4040-262 • Rev M • 08/09



Symptom

Possible Cause

Corrective Action

. Pilot won’t light. The

ignitor/module makes

noise, but no spark.

A. Incorrect wiring.

Verify “S” wire (white) for sensor and “I” wire (orange) for ignitor are

connected to correct terminals on module and pilot assembly.

B. Loose connections or electrical

shorts in the wiring.

Verify no loose connections or electrical shorts in wiring from module

to pilot assembly. Verify connections underneath pilot assembly are

tight; also verify connections are not grounding out to metal chassis,

pilot burner, pilot enclosure, mesh screen if present, or any other

metal object.

C. Ignitor gap is too large.

Verify gap of igniter to right side of pilot hood. The gap should be

approximately .7 inch or /8 in. ( mm).

D. Module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove

ignitor wire “I” from module. Place a grounded wire about 3/16 in.

(5 mm) away from “I” terminal on module. Place ON/OFF rocker

switch or wall switch in ON position. If there is no spark at “I” terminal

module must be replaced. If there is a spark at “I” terminal, module

is fine. Inspect pilot assembly for shorted sparker wire or cracked

insulator around electrode. Replace pilot if necessary.

2. Pilot won’t light, there is no

noise or spark.

A. No power or transformer

installed incorrectly.

Verify that transformer is installed and plugged into module. Check

voltage of transformer under load at spade connection on module

with ON/OFF switch in ON position. Acceptable readings of a good

transformer are between .2 and 2.8 volts AC.

B. A shorted or loose connection

in wiring configuration or wiring

harness.

Remove and reinstall the wiring harness that plugs into module.

Verify there is a tight fit. Verify pilot assembly wiring to module.

Remove and verify continuity of each wire in wiring harness.

Replace any damaged components.

C. Improper wall switch wiring.

Verify that 110/VAC power is “ON” to junction box.

D. Module not grounded.

Verify black ground wire from module wire harness is grounded to

metal chassis of appliance.

E. Module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove

ignitor wire “I” from module. Place ON/OFF rocker switch or wall

switch in ON position. If there is no spark at “I” terminal module must

be replaced. If there is a spark at “I” terminal, module is fine. Inspect

pilot assembly for shorted sparker wire or cracked insulator around

electrode.

. Pilot sparks, but Pilot will

not light.

A. Gas supply.

Verify that incoming gas line ball valve is “open”. Verify that inlet

pressure reading is within acceptable limits.

B. Ignitor gap is incorrect.

Verify that spark gap from ignitor to pilot hood is .7 in. or /8 in (

mm).

C. Module is not grounded.

Verify module is securely grounded to metal chassis of appliance.

D. Module voltage output / Valve/

Pilot solenoid ohms readings.

Verify battery voltage is at least 2.7 volts. Replace batteries if voltage

is below 2.7.

A. Intellifire Ignition System (continued)

4. Pilot lights but continues

to spark, and main burner

will not ignite. (If the pilot

continues to spark after

the pilot flame has been lit,

flame rectification has not

occurred.)

A. A shorted or loose connection

in flame sensing rod.

Verify all connections to wiring diagram in manual. Verify

connections underneath pilot assembly are tight. Verify connections

are not grounding out to metal chassis, pilot burner, pilot enclosure

or screen if present, or any other metal object.

B. Poor flame rectification or

contaminated flame sensing

rod.

With fixed glass assembly in place, verify that flame is engulfing

flame sensing rod on left side of pilot hood. Flame sensing rod

should glow shortly after ignition. Verify correct pilot orifice is

installed and gas inlet is set to pressure specifications. Clean flame

sensing rod with emery cloth to remove any contaminants that may

have accumulated on flame sensing rod.

C. Module is not grounded.

Verify module is securely grounded to metal chassis of appliance.

Verify that wire harness is firmly connected to the module.

D. Damaged pilot assembly or

contaminated flame sensing

rod.

Verify that ceramic insulator around the flame sensing rod is not

cracked, damaged, or loose. Verify connection from flame sensing

rod to white sensor wire. Clean flame sensing rod with emery cloth

to remove any contaminants that may have accumulated on flame

sensing rod. Verify continuity with a multimeter with ohms set at

lowest range. Replace pilot if any damage is detected.

E. Module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove

ignitor wire “I” from module. Place ON/OFF rocker switch or wall

switch in ON position. If there is no spark at “I” terminal module must

be replaced. If there is a spark at “I” terminal, module is fine.

5. The pilot and main

burner extinguish while in

operation.

A. No LP in tank.

Check the LP (propane) tank. Refill the fuel tank.

B. Improper gas inlet pressure.

Verify with manometer. NG should read 5-4 inches w.c. LP should

read 0-4 inches w.c.

C. Inner vent pipe leaking exhaust

gases back into the system.

Check venting system for damage. Replace/repair improperly

assembled pipe sections.

D. Glass installed improperly.

Check to ensure glass is installed properly. Replace glass panel

assembly.

E. Improper vent cap installation. Check for proper installation and freedom from debris or blockage.

F. High limit switch has been

automatically activated.

This appliance is equipped with an auto reset high limit switch

which will shut down the appliance if it spills under flue blockage or

excessive negative pressure conditions. Shut off the appliance and

the gas supply. Do not attempt to operate the appliance until it has

been examined by a qualified service technician.