Table 5. Spark Model Specific Connectors.

a

Indicates optional connections based on configuration.

Table 6. Pin Configuration.

Temperature Control

Temperature control setpoint on the module can be
adjusted as described in the following sections. Some
modules with temperature control also include a three-
digit display on the printed circuit board to facilitate
adjustments and troubleshooting.

For modules that do not include temperature control on
the module refer to the Honeywell Installation Instructions
for the specific interface module or the appliance
manufacturer’s instructions. A separate automatic gas
shutoff device is not required in a system that uses this
control to meet requirements for CSA International ANSI
Z21.87 and UL 353.

The overall range of the setpoint is model-dependent but
is within 130°F to 240°F (54°C to 116°C). Select devices
may have different ranges.

Adjusting Settings or Models with “On-

Board” Display

To discourage unauthorized changing of settings, a
procedure to enter the adjustment mode is required. To
enter the adjustment mode, press the UP, DOWN, and I

buttons (see Fig. 1) simultaneously for three seconds.
Press and release the I button until the parameter

requiring adjustment is displayed:

Connection

Pin

Mating Plug

Description

Line Voltage Input/White

1 of 4

Molex

®

50-81-1040

L1

2 of 4

Earth Ground

3 of 4

Earth Ground

4 of 4

Neutral

Induced Draft Blower (Combustion Air

a

)/White

1 of 6

Molex

®

39-01-2060

Earth Ground

2 of 6

N/C

3 of 6

Neutral

4 of 6

N/C

5 of 6

L1 Relay Out

6 of 6

N/C

Vent Damper

a

/White

1 of 6

24 Vac

2 of 6

Damper E.S.
Feedback

3 of 6

24V Common if
damper connected

4 of 6

24V Common

5 of 6

Damper Activation

6 of 6

N/C

Spark Rod

1 of 1

1/4 in. female quick-
connect

Connection to Spark
Rod

On/Off Circulator

a

/Red

1 of 2

Molex

®

50-84-1021

L1 Relay Out

2 of 2

Neutral

Wire Harness Housing Pin Configuration

Pin/Socket

Molex

®

Number

Line In

pin

02-08-2004

Transformer Primary

socket

02-08-1002

Transformer Secondary socket

02-08-1002

Circulator

pin

02-08-2004

Damper

pin

03-06-2103

Inducer

socket

39-00-0039

Control

socket

02-08-1002

Sensor 1

socket

08-50-0106

Sensor 2

socket

08-50-0106

E-COM Diagnostic

socket

08-50-0114