Appendix g - idr technical specifications – Honeywell SUB Series Interval Data Recorders 62-0342-01 User Manual

Page 12

Advertising
background image

SUB SERIES INTERVAL DATA RECORDERS

62-0342—01

12

APPENDIX G - IDR TECHNICAL SPECIFICATIONS

Enclosure:

Lockable steel JIC box NEMA 12.

Dimensions:

9.5” H x 6.75” W x 3.875” D.

Knockouts:

Three (3) on bottom of enclosure (3/4” Cond.)

Power Supply:

Powered by meter or optional 120 VAC adapter.

Back Up:

Lithium Power Cell LTC-3PN (10 year lifetime)

LED Indicators:

Input pulse, CPU operation, alarm, power, communication

Inputs

SUBIDR-8:

Eight (8) eight-pin modular ports

or

Eight (8) 2-screw plug-in terminals

SUBIDR-16:

Sixteen (16) eight-pin modular ports

or

Sixteen (16) 2-screw plug-in terminals

or

Eight (8) eight-pin modular ports and eight (8) 2-screw plug-in terminals

Max Pulse Input:

<600 pulses per minute (50% duty cycle)

Data Storage:

12 days @ 5-minute sampling intervals

36 days @ 15-minute sampling intervals

Interface with:

Honeywell submeters, Electric utility meters, third-party submeters, gas meters, water meters, BTU meters and any meter

equipped with a contact pulse output (using available 2-screw terminals.)

Power Consumption:

2 watts maximum, 1.2 watts typical

Processor:

8-bit; 14 MHz main clock

Real-Time Clock:

100-year clock/calendar. Automatically makes changes to standard/daylight savings time.

Communications:

Serial, RS-485, 3-wire. Optically isolated from all other circuits. 9600 bps standard; provisions for 19200 or 2400 bps.

Advertising