Section 6: gas information, Warning, Gas information – Heat & Glo Fireplace HEAT & GLO TWILIGHT-II User Manual

Page 12

Advertising
background image

Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/05

12

NOTE: Have the gas supply line installed in accordance
with local building codes, if any. If not, follow ANSI 223.1.
Installation should be done by a qualified installer approved
and/or licensed as required by the locality. (In the
Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fitter.)

A. Fuel Conversions

WARNING

Fire Risk.
Explosion Hazard.
High pressure will damage valve.
• Disconnect gas supply piping BEFORE

pressure testing gas line at test pressures
above 1/2 psig.

• Close the manual shutoff valve BEFORE

pressure testing gas line at test pressures
equal to or less than 1/2 psig.

B. Gas Pressures

C. Gas Connection

WARNING

Verify inlet pressures.
• High pressure may cause overfire condition.
• Low pressure may cause explosion.
• Verify minimum pressures when other

household gas appliances are operating.

Install regulator upstream of valve if line
pressure is greater than 1/2 psig.

Proper input pressures are required for optimum appliance
performance. Gas line sizing requirements need to be made
following NFPA51.

Gas Information

6

NOTE: Gas line may be run from either side of the
appliance provided the hole in the outer wrap does NOT
exceed 2-1/2 inches in diameter and does not penetrate
the firebox.

NOTE: A listed (and Commonwealth of Massachusetts ap-
proved) 1/2 inch (13mm) T-handle manual shut-off valve and
flexible gas connector are connected to the 1/2 inch (13mm)
control valve inlet.
• If substituting for these components, please consult

local codes for compliance.

NOTE: The gap between the supply piping and gas access
hole ma

y be caulked with high temperature caulk or stuffed

with non-combustible un-faced insulation to prevent cold
air infiltration.

Pressure requirements for appliance are shown in the table
below. Minimum pressures must be met when other
household gas appliances are operating.

Pressure

Natural Gas

Propane

Minimum

5.0 inches

11.0 inches

Inlet Pressure

w.c.

w.c.

Maximum Inlet

14.0 inches

14.0 inches

Gas Pressure

w.c.

w.c.

Manifold

3.5 inches

10.0 inches

Pressure

w.c.

w.c.

Before making gas connections ensure that appliance
being installed is compatible with the available gas type.

Any natural or propane gas conversions necessary to meet
the appliance and locality needs must be made by a quali-
fied technician using Hearth & Home Technologies speci-
fied and listed gas conversion kit.

Refer to Reference Section 13 for location of gas line ac-
cess in appliance.

WARNING

Gas Leak Risk
• Support control when attaching pipe to

prevent bending gas line.

Н