Termination Locations

4

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

FP

= APPLIANCE OPENING

X

= AIR SUPPLY INLET

= AREA WHERE APPLIANCE IS NOT PERMITTED

A

= 0" ......................... clearances above grade, veran-

da, porch, deck or balcony

B*

= 12" ....................... clearances to window or door

that may be opened, or to per-
manently closed window.

D**

= 31" ....................... vertical clearance to ventilated

soffit located above the hood
within a horizontal distance of 2
feet (60 cm) from the center-line
of the hood

E**

= 31" ....................... clearance to unventilated soffit

F

= 9" ........................ clearance to outside corner

G*

= 12" ....................... clearance to inside corner

H

= 3 ft. (Canada) ...... not to be installed above a gas

meter/regulator assembly within
3 feet (90cm) horizontally from the
center-line of the regulator

I

= 3 ft. (U.S.A.)

6 ft. (Canada) ...... clearance to service regulator

vent outlet and electric service

J

= 9" (U.S.A.)

12" (Canada) ........ clearance to non-mechani-

cal air supply inlet to build-
ing or the combustion air in-
let to any other appliance

K

= 3 ft. (U.S.A.)

6 ft. (Canada) ......... clearance to a mechanical

air supply inlet

L*** = 54” ......................... clearance above paved

sidewalk or a paved driveway
located on public property

M**** = 31" ......................... clearance under veranda,

porch, deck, balcony or overhang

60” ......................... vinyl

N

= 12” ......................... non-vinyl siding

36” ......................... vinyl siding

P

= 8 ft.

(See Note 1)

(See Note 1)

(See Note 2)

Q

MIN

R

MAX

Twilight-II

10 feet

2 x Q

ACTUAL

1 additional termination cap

Q + 3 feet

1 x Q

ACTUAL

2 additional termination caps

Q + 6 feet

2/3 x Q

ACTUAL

3 additional termination caps

Q + 9 feet

1/2 x Q

ACTUAL

R

MAX

= (2 / # caps plus appliance) x Q

ACTUAL

D

E

L

FP

A

H

M

X

J or K

I

A

G

F

FP

FP

FP

FP

FP

B

B

B

** 60” minimum for vinyl clad soffits.

*** a appliance shall not open directly above a sidewalk or paved

driveway which is located between two single family dwellings
and serves both dwellings.

****

only permitted if veranda, porch, deck or balcony is fully open on a
minimum of 2 sides beneath the floor, or if the screened porch
guidelines are followed.

NOTE 1: Local codes or regulations may require different clearances.

NOTE 2: Termination in an alcove space (spaces open only on one side
and with an overhang) are permitted with the dimensions specified for
vinyl or non-vinyl siding and soffits. 1. There must be 3 feet minimum
between terminations or between the appliance and termination. 2. All
mechanical air intakes within 10 feet of a termination must be a minimum of
3 feet below the appliance hood. 3. All gravity air intakes within 3 feet of
the appliance hood must be a minimum of 1 foot below the termination.

* 36” minimum for vinyl windows or vinyl siding.

This appliance is approved for installation onto screened porches
with the following guidelines:

Fire Risk. Explosion Risk.

Maintain vent termination minimum clearances as specified.

WARNING

Figure 4.1 Minimum Clearances for Appliance Opening

NOTE: There may be some odor and small amounts of soot
associated with venting the Twilight-II onto a screened porch.
Ensuring good cross draft ventilation and routine maintenance of
the appliance will maximize comfort and cleanliness.

Minimum porch area: 96 square feet
Minimum ceiling height: 92 inches
Minimum two walls must be screened
Minimum top of screen height, side walls: 6 ft. 8 in.
Minimum screen area: 64 square feet

A. Appliance Opening
Minimum Clearances