TZ-3 TOTALZONE® ZONE CONTROL PANEL

7

68-0223-2

Multi-Stage: Wire the equipment as shown in Fig. 14 using the
W2 terminal for second stage of heat and the W3 terminal for
third stage of heat. Wire the Y2 for second stage of cooling.

Fig. 14. Heating and cooling equipment.

Heat Pump Equipment

Wire the heat pump to the equipment terminals on the panel
as shown in Fig. 15. Refer to manufacturer’s instructions for
additional wiring instructions and substitute the TZ-3
equipment terminals for the thermostat terminals shown.

IMPORTANT

Some heat pump manufacturers (such as York and
Trane) use the B terminal as the transformer com-
mon. Do not connect the common from the equip-
ment to the zone control panel.

Two-speed Compressor: Wire the second stage compressor
to both Y2 and W2. Wire the auxiliary heat to W3. Remove the
two-stage emergency heat jumper and install a jumper from
W3 to E.

Fossil Fuel Kits with Heat Pumps: Wire these systems like
Fig.15 but use the manufacturer’s fossil fuel kit. Wire the
Trane XL 1800 and the TAYPLUS 103 as shown in Fig. 16.
The recommended thermostat is theT8611G2051.

C

G

Y

R W

ZONE 1

THERMOSTAT

24V, 40 VA
TRANSFORMER

M19074

W2

W3

E

W1

B

G

R

O

Y1

Y2

TL

TL

2 STAGE

EM HEAT

MODEL TZ-3

C

R

OC

OC

TR1

TR2

HEAT

TO TERMINAL AZ1 ON TAZ (IF USED)

OUTDOOR CONDENSING UNIT

HVAC CONTROLS

ZoneMAX

Add-A-Zone

TM

COOL

PURGE

FAN

EM.HT

ZONE 1

ZONE 2

ZONE 3

BOOT

OVERRIDE

PURGE

REMOTE OCCUPIED/

UNOCCUPIED CONTROL

(CLOSE IN UNOCCUPIED)

ON

OFF

Emergency Heat

ON

1

L

W2

G

Y

R W M6 M4 M1

THERMOSTAT

MOTOR

2 3 4 5 6 7 8

OCCUP

REMOTE

UNOCCUP

Zone-A-Lone

C

1

2

3

X

4

5

6

Z

G

Y

R W

ZONE 3

THERMOSTAT

MODEL ARD OR
ZD DAMPERS

ZONE 2

L

W2

G

Y

R W M6 M4 M1

THERMOSTAT

MOTOR

ZONE 1

L

W2

G

Y

R W M6 M4 M1

THERMOSTAT

MOTOR

ZONE 3

C

G

Y

R W

ZONE 2

THERMOSTAT

1

2

3

X

4

5

6

Z

OPPOSED BLADE DAMPER MOTORS

AZ1

AZ2

TO TERMINAL AZ2 ON TAZ (IF USED)

ZoneMAX

TEMPERATURE

SENSOR

TM

15 MINUTES

10 MINUTES

5 MINUTES

20 MINUTES

25 MINUTES

30 MINUTES

STAGE TIMER

130 F

MAXIMUM

TEMPERATURE

120 F

110 F

140 F

150 F

160 F

W

W2

24V TRANSFORMER

FAN RELAY

HEAT RELAY

R

Y

Y2

C

G

Advertising