International electrical symbols, Specifications, General specifications – Fluke 115 User Manual

Page 3

Advertising
background image

Digital Multimeters

International Electrical Symbols

3

International Electrical Symbols

Table 1 lists the international symbols that appear in this document and on the Meter.

Table 1. Electrical Symbols

Symbol Description Symbol

Description

B

AC (Alternating Current)

I

Fuse

F

DC (Direct Current)

T

Double Insulated

X

Hazardous voltage

W

Important Information; Refer to manual

N

Battery (Low battery when shown on the
display.)

J

Earth ground

~

Do not dispose of this product as unsorted municipal waste. Contact Fluke or a qualified recycler for
disposal.

Specifications

Accuracy is specified for 1 year after calibration at operating temperatures of 18

°

C to 28

°

C, with relative humidity at 0 % to 90 %. Extended

specifcifications are available at www.fluke.com.

General Specifications

Maximum voltage between any
terminal and earth ground
................................... 600 V

Surge Protection................................................... 6 kV peak per IEC 61010-1 600V CAT III,

Pollution Degree 2

W

Fuse for A input (115 & 117 only):.................. 11 A, 1000 V FAST 17 kA Fuse (Fluke PN 803293)

Display ................................................................... Digital: 6,000 counts, updates 4/sec

Bar Graph: 33 segments, updates 32/sec

Temperature .......................................................... Operating: -10 °C to +50 °C

Storage: -40 °C to +60 °C

Temperature Coefficient ...................................... 0.1 x (specified accuracy)/

°

C (<18

°

C or >28

°

C)

Operating Altitude ................................................ 2,000 meters

Battery ................................................................... 9 Volt Alkaline, NEDA 1604A / IEC 6LR61

Battery Life ............................................................ Alkaline: 400 hours typical, without backlight

Safety Compliances.............................................. Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No 61010-1-04, UL 6101B

(2003) and IEC/EN 61010-1 2nd Edition for measurement Category III, 600 V, Pollution
Degree 2, EMC EN61326-1

Certifications......................................................... UL, P, CSA, TÜV, ; (N10140), VDE

IP Rating (dust and water protection)................. IP42

Advertising
This manual is related to the following products:

116, 117, 114