Installation instructions, Outside top exhaust, Attach the mounting plate to the wall a1. 12 – FRIGIDAIRE 316495063 User Manual

Page 12: Installation overview, Vertical duct)

Advertising
background image

Place the mounting plate against the wall and
insert the toggle wings into the holes in the wall
to mount the plate.

NOTE: Before tightening toggle bolts and wood
screw, make sure the tabs on the mounting plate
touch the bottom of the cabinet when pushed
flush against the wall and that the plate is properly
centered under the cabinet.
CAUTION: Be careful to avoid pinching fingers
between the back of the mounting plate and the wall.

Tighten all bolts. Pull the plate away from the wall
to help tighten the bolts.

3

4

ATTACH THE MOUNTING
PLATE TO THE WALL

A1.

12

Attach the plate to the wall using toggle bolts.
At least one wood screw must be used to attach
the plate to a wall stud.

Remove the toggle wings from the bolts.
Insert the bolts into the mounting plate
through the holes designated to go into drywall
and reattach the toggle wings to

3

4

w (19 mm) onto

each bolt.

1

INSTALLATION OVERVIEW

A1. Attach Mounting Plate to Wall
A2. Prepare Top Cabinet

Mount Microwave Oven

A5.

Adjust Exhaust Adaptor

A6.

Wall

Mounting

Plate

Spacing for Toggles
More Than Wall
Thickness

Bolt End

Toggle
Bolt

Toggle Wings

To use toggle bolts:

Installation Instructions

2

OUTSIDE TOP EXHAUST

(Vertical Duct)

A

IMPORTANT NOTES:

Make sure the screws for the
blower motor and blower plate
are securely tightened when
they are reinstalled. This will
help to prevent excessive
vibration.

Make sure the motor wiring has
been properly routed and secured,
and that the wires are not pinched.

A7. Connect Ductwork

A3.

A4. Check Damper Operation

Adapting Microwave Blower for

Outside Top Exhaust

Advertising