background image

Attach the exhaust adaptor to the rear of the
oven by sliding it into the guides at the top
center of the back of the oven.

AFTER: Fan Blade
Openings Facing Back

Place the blower unit back into the opening.

Replace the blower plate in the same position
as before with the screw. Make sure the screw
is tight.

Roll the blower unit 90° so that fan blade
openings are facing out the back of the
microwave.

ADAPTING MICROWAVE
BLOWER FOR OUTSIDE
BACK EXHAUST (cont.)

B5.

Rotate blower unit counterclockwise 180°.

Before Rotation

After Rotation

Gently remove the wires from the grooves.

Reroute the wires through grooves on other side
of the blower unit.

Before Rerouting

After Rerouting

Wires Routed Through Right Side

Wires Routed Through Left Side

Back of
Microwave

Back of
Microwave

Blower Plate

Blower Motor
Screw

Secure the blower unit to the microwave with
the original screw.

Before Rolling

After Rolling

Back of
Microwave

End A

End B

Back of
Microwave

Back of
Microwave

CAUTION: Do not pull or stretch the blower
unit wiring. Make sure the wires are not
pinched, and that they are properly secured.

NOTE: The blower unit exhaust

openings should match exhaust

openings on rear of microwave oven.

Installation Instructions

Push in securely until it is in the lower locking
tabs. Take care to assure that the damper hinge
is installed so that it is at the top and that the
damper swings freely.

Guide

Guide

Adaptor

Locking Tabs

Back of
Microwave

Back of
Microwave

Roll the blower unit 90°

Back of
Microwave

3

4

5

6

7

8

9

10

Before Rotation

After Rotation

18