IMPORTANT: Make sure you have converted
the side burner to Liquid Propane prior to
completing the following steps.

1. Remove the LP gas hose assembly from the

flare fitting. (this has the regulator attached to
it.) (See Fig. 12)

2. Using an adjustable wrench remove the

flare fitting coming out of the bottom of the
grill.Once the flare fitting is removed the main
gas pipe will be showing under grill. (See Fig. 13)

4. Using pipe sealant, attach the “T” Fitting to the

main gas pipe coming out of the bottom of the
grill and tighten with a wrench. (See Fig. 14)

5. Using pipe sealant, attach a 3/8” flared fitting to

the side and bottom of the “T” fitting. (See Fig.
15)

6. Attach the Flex Line to the fitting on the side of

the “T” fitting. Connect the other end of the flex
line to the side burner valve. (See Fig. 16)

Note: This line can be extended using a 3/8”
flared coupling and an additional flex line if
necessary.

7. Attach the LP gas hose assembly to the

bottom flared fitting. (See Fig. 17)

Fig. 12

Fig. 13

Fig. 14

Fig. 15

Fig. 16

Fig.17

Be sure your L.P. cylinder has an overfill
protection device on it. Max inlet pressure
cannot exceed 10”-11” water column.

Flex Line

Gas Hose

Main Gas Pipe

Attach to fitting

“T” fitting

LP hose/
regulator
supplied
with grill.