8installation, Replacement parts, Electrical connections for 4-wire system – FRIGIDAIRE 134296400 User Manual

Page 8

Advertising
background image

8

INSTALLATION

1. GAS CONNECTION (Gas dryers only)

a. Remove the shipping cap from gas pipe at the rear of the

dryer.

NOTE:

DO NOT connect the dryer to L.P. gas service without
converting the gas valve. An L.P. conversion kit must be
installed by a qualified gas technician.

b. Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or approved pipe

from gas supply line to the 3/8 inch (0.96 cm) pipe located
on the back of the dryer. Use a 1/2 inch to 3/8 inch (1.27 cm
to 0.96 cm) reducer for a connection. Apply an approved
thread sealer that is resistant to the corrosive action of
liquefied gases on all pipe connections.

c. Open the shutoff valve in the gas supply line.
d. Test all connections by brushing on a soapy water solution.

NEVER TEST FOR GAS LEAKS WITH AN OPEN FLAME.

2. Connect the exhaust duct to outside exhaust system. Use duct

tape to seal all joints.

3. With the dryer in its final position, adjust one or more of the legs

until the dryer is resting solid on all four legs. Place a level on top
of the dryer. THE DRYER MUST BE LEVEL AND RESTING SOLID
ON ALL FOUR LEGS.

4. Plug the power cord into a grounded outlet. NOTE: Check to

ensure the power is off at circuit breaker/fuse box before
plugging the power cord into the outlet.

5. Turn on the power at the circuit breaker/fuse box.

Before operating the dryer, make sure the dryer area

is clear and free from combustible materials, gasoline, and other
flammable vapors. Also see that nothing (such as boxes, clothing,
etc.) obstructs the flow of combustion and ventilation air.

6. Run the dryer through a cycle check for proper operation.

NOTE: On gas dryers, before the burner will light, it is necessary
for the gas line to be bled of air. If the burner does not light
within 45 seconds the first time the dryer is turned on, the safety
switch will shut the burner off. If this happens, turn the timer to
"OFF" and wait 5 minutes before making another attempt to
light.

7. If your dryer does not operate, please review the "Avoid Service

Checklist" located in your Owner's Guide before calling for
service.

8. Place these instructions in a location near the dryer for future

reference.

NOTE:

A wiring diagram is located inside the dryer console or
under the top panel.

REPLACEMENT PARTS

If replacement parts are needed for your dryer, contact the source
where you purchased your dryer.

Label all wires prior to disconnection when servicing

controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.

Destroy the carton and plastic bags after the dryer is

unpacked. Children might use them for play. Cartons covered with
rugs, bedspreads, or plastic sheets can become airtight chambers
causing suffocation. Place all materials in a garbage container or
make materials inaccessible to children.

The instructions in this manual and all other literature

included with this dryer are not meant to cover every possible
condition and situation that may occur. Good safe practice and
caution MUST be applied when installing, operating and
maintaining any appliance.

ELECTRICAL CONNECTIONS

FOR 4-WIRE SYSTEM

Non-Canadian ELECTRIC Dryer

1. Remove the screws securing the terminal block access cover and

the strain relief mounting bracket located on the back of the dryer
upper corner.

2. Install a U.L. approved strain relief in the entry hole of the mounting

bracket. Finger tighten the nut only at this time.

3. Remove the ground wire from the green ground screw located

above the terminal block.

4. Thread a U.L. approved 30 amp power cord, NEMA 14-30 type ST

or SRDT through the strain relief.

5. Attach the green power cord ground wire to the cabinet with the

green ground screw.

6. Attach the white (neutral) power cord conductor from the power

cord and the neutral ground wire from the dryer harness to the
silver-colored center terminal on the terminal block. Tighten the
screw securely.

7. Attach the red and black power cord conductors to the outer

brass-colored terminals on the terminal block.

Do not make a sharp bend or crimp wiring/ conductor

at the connections.

8. Tighten the screws securing the cord restraint firmly against the

power cord.

9. Tighten the strain relief nut securely so the strain relief does not

turn.

10. Reinstall the terminal block access cover.

TYPICAL 4
CONDUCTOR

RED 240V

BLACK

WHITE

GREEN

30 AMP NEMA 14-30 TYPE SRDT OR

30 AMP NEMA 14-30 TYPE SRDT OR

30 AMP NEMA 14-30 TYPE SRDT OR

30 AMP NEMA 14-30 TYPE SRDT OR

30 AMP NEMA 14-30 TYPE SRDT OR

TYPICAL 4
CONDUCTOR

STRAIN

RELIEF

MOUNTING

BRACKET

NUT

TIGHTEN NUT
TO THESE
THREADS

POWER
CORD

RED

WHITE

BLACK

TERMINAL
BLOCK

SILVER TERMINAL

GREEN
GROUND
SCREW

GREEN POWERCORD
GROUND WIRE

NEUTRAL
GROUND
WIRE

Advertising