2 communication unit, How to install the cu – Furuno FELCOM 250 User Manual

Page 18

Advertising
background image

1. HOW TO INSTALL THE UNIT

12

1.2

Communication Unit

Select a location for the communication unit (CU) by following the information shown below.

• The unit is not waterproof. Keep the unit away from water splash.
• Keep the unit away from direct sunlight.
• The temperature and humidity must meet the requirements shown in the equipment specifica-

tions.

• Set the unit away from the exhaust pipes and vents.
• The installation location must have enough cool air.
• Install the unit where shock and vibration meet the requirements shown in the equipment spec-

ifications.

• Keep the unit away from the equipment that creates an electromagnetic field, for example, mo-

tor and generator.

• For maintenance and checking, leave enough space at the sides and rear of the unit. Refer to

the outline drawing and provide some additional length in cables.

• Follow the recommended compass safe distances shown on page i to prevent the interference

to a magnetic compass.

How to install the CU

Follow the procedure shown below to install the CU on a desktop. See the outline drawing on page
D-3 for details.

1. Place the template (supplied) of the CU on the installation site.
2. Mark the points for four pilot holes and makes the pilot holes for 5x50 self-tapping screws.
3. Put the unit on the installation site and fix it with four 5x50 self-tapping screws (supplied).

Note: It is necessary to install the Communication Unit on a desktop to comply with IPX2 (drip-
ping) standard. Refer to section 2.5 for directions to how to install on a desktop.

350±0.5 mm (13.78

"

)

52.5 mm

(2.07

")

160±0.5 mm (6.30

")

375 mm (14.76

"

)

SIM CARD INSIDE

POWER OFF BEFORE INSERTING

OR REMOVING SIM

POWER

I

POWER

1

TX

2

3

4

STATUS

Inmarsat FleetBroadband

READY

4-

φ

6 mm (0.24

"

)

Fixing holes

Advertising
This manual is related to the following products: