Connecting the Power/Data Cable to Power

1. Use a test light or a voltmeter to determine the polarity of the voltage source.
2. Connect the red (+ or positive) wire to the positive voltage terminal. (If you use the

fuse block on the boat, route the positive connection through the fuse, as shown on the

diagram.)

3. Connect the black (- or ground) wire to the negative voltage terminal.
4. Install or check the 3 A fuse (in the in-line fuse holder, or on the fuse block of the boat).

Connecting the Power/Data cable to a NMEA 0183 Device

(optional)

You can connect the GPSMAP 700 series chartplotter to other NMEA 0183-compatible

equipment, such as a DSC or AIS device. Refer to the wiring diagram for connecting the chartplotter to NMEA 0183-compatible devices.

Wiring a GPSMAP 700 Series Chartplotter to a Standard NMEA 0183 Device

+

-

>

>

>

>

Red (power)

Black (ground)

Brown (in)

Blue (out)

Wire color

Power

Power ground

NMEA Ground

NMEA Rx/A (+)
NMEA Tx/A (+)

NMEA 018-compatible

device

GPSMAP 700

series

chartplotter

Battery

10– Vdc

Fuse

 A

Wire function

to connect the power/data cable to a NMEA 0183 device:

1. For Garmin devices, the ground (black) wires serve as NMEA 0183 ground and must be attached together or on the same terminal as the

NMEA 0183 ground on your NMEA 0183 device. Refer to the wiring diagram of your NMEA 0183 device for wire identification.

2. Connect the blue (NMEA 0183 port 1 out) wire from the GPSMAP 700 power/data cable to the NMEA 0183 in (or Rx/A +) wire from the

NMEA 0183 device, and the brown (NMEA 0183 port 1 in) wire to the NMEA out (or Tx/A +) wire from the NMEA 0183 device.

3. Repeat step 2 using the gray (NMEA 0183 port 2 out) and violet (NMEA 0183 port 2 in) wires for an additional NMEA 0183 device.
4. Set the serial port (or ports) on the chartplotter to use NMEA 0183 data (standard or high-speed). See the GPSMAP 700 Series Owner’s

Manual for more information.

Connecting the Power/Data Cable to a Lamp or to a Horn (optional)

The GPSMAP 700 series chartplotter can be used with a lamp, a horn, or both, to sound or flash an alert when the chartplotter displays a

message. The alarm does not need to be wired for the chartplotter to function. The alarm circuit switches to a low-voltage state when the alarm

sounds. The maximum current is 100 mA, and a relay is needed to limit the current from the chartplotter to 100 mA. To manually toggle visual

and audible alerts, install single-pole, single-throw switches.

Wiring to a Lamp, a Horn, or Both

+

-

GPSMAP 700 series

chartplotter

Wire

Color

Red (power)

Black (gnd)

Yellow (alarm)

Battery

10– Vdc

Relay

100 ma max

coil current

Horn

Lamp

Fuse

 A

Fuse Block Example

+

2A

3A

-

+

Boat ground

 A fuse

To 10– Vdc boat supply

To device

Fuse Block Example

+

2A

3A

-

+

Boat ground

 A fuse

To 10– Vdc boat supply

To device