Adapting microwave blower for recirculation, Adapting microwave blower for recirculation , 21, Installation instructions – GE DE68-02957A User Manual

Page 20: Adapting microwave blower for recirculation c3. 20

Advertising
background image

ADAPTING MICROWAVE
BLOWER FOR RECIRCULATION

C3.

20

Installation Instructions

2

1 Remove the back top center blower motor door

retaining screw.

Open the blower door by lifting it up at the back
side of the microwave. Remove and save the top
and back retaining screws that hold the blower
motor in the microwave.

Back of
Microwave

Blower Motor

Blower Door
Screw

Retaining
screw

Roll the assembled blower unit so that the
black-colored exhaust outlet faces the front of
the microwave and the gray-colored inlet sleeve
faces downward.
NOTE:

The gray-colored sleeve opening must

ALWAYS face downward to ensure proper
operation of the microwave.

5

4

3 Carefully slide the blower motor toward the right,

and lift it partially out of the opening. Note: The
blower wires are long enough to allow flexible
handling while performing these steps. Disconnect
the wires only if it is necessary for additional
flexibility.

Remove the two screws holding the gray colored

inlet sleeve to the blower unit. Rotate the gray
sleeve as shown until the gray arrow lines up with
the “R”, Recirculating exhaust. Reinstall the two
screws.

Back of
Microwave

Back of Microwave

Back of
Microwave

Remove screws from
Gray Inlet Sleeve

Retaining
screw

Black
Exhaust
Outlet Facing
the Front

Must Face
Downward

Advertising
This manual is related to the following products: