6

309739

Troubleshooting

Problem

Cause

Solution

Gun fails to dispense when trigger is
actuated

Material lodged in nozzle

Follow Pressure Relief Procedure,
page 5. Clear nozzle of blockage.

Material supply, hose, passages,
clogged

Check material supply settings,
hoses, etc. for proper material supply.

Verify integrity of trigger pin through
yoke. Repair or replace cartridge
assembly as necessary.

Gun fails to dispense when trigger is
engaged

Tension of trigger needs adjustment

Check spring tension adjustment at
rear of gun. Spring tension should be
adjusted to allow approximately 1/32
in. of free play on trigger.

Verify integrity of trigger pin through
yoke. Repair or replace cartridge
assembly as necessary.

Needle and seat adapter loose or
worn

Check that seat adapter is tightened
firmly and flush to gun body.

Needle and seat adapter worn.
Replace components as necessary.

Seal leakage

Packing adjustment nut not snug

Follow Pressure Relief Procedure,
page 5. Tighten packing adjustment
nut.

Worn seals and packings

Rebuild gun as necessary.

Material leaks from gun inlet swivel

Worn seals

Replace seals.