Installation

18

WARNING:

TEST FOR LEAKS

A complete gas tightness check must be performed at
the installation site.

CAUTION:

To prevent fire or explosion hazard, DO NOT use or
permit sources of ignition in the area while performing
a leak test. Perform leak test outdoors only. Never
perform a leak test with fire or flame. DO NOT SMOKE
WHILE PERFORMING THE LEAK TEST.
• Use an approved non-corrosive leak detection

solution or create a soapy solution of equal parts
mild dishwashing detergent and water.

• Check to be sure all controls are in the OFF position.
• Turn on the fuel supply. For natural gas, turn manual

shut-off valve handle 1/4 turn to align with gas flow.
For LP, turn cylinder valve knob counterclockwise one
full rotation.

• Apply liquid leak detector generously on all

connections and fittings. See illustrations.

• If growing bubbles appear on any connection point,

IMMEDIATELY turn off the gas supply.

To stop a gas leak:

• Turn off the fuel supply.

• Turn on control knobs to release pressure. Turn

controls OFF.

• Wash off soapy solution and towel dry.
• Tighten the loose joint and perform a new leak test.

Natural Gas Leak

Test Points

LP Gas Leak

Test Points

To Cooktop

3/8"

Flare Tee

From Regulated

LP Tank

To Manifold

of Grill

LP Gas Leak Test Points

With Cooktop