Troubleshooting tips, Before you call for service – GE 183D5580P236 User Manual

Page 40

Advertising
background image

Operating Instructions

Safety Instructions

Installation Instructions

Tr

oubleshooting T

ips

Consumer Support

40

Before you call for service…

Troubleshooting Tips
Save time and money! Review the charts on the following
pages first and you may not need to call for service.

Problem

Possible Causes

What To Do

Top burners do not light

Plug on range is not completely

• Make sure electrical plug is plugged into a live,

or do not burn evenly

inserted in the electrical outlet.

properly grounded outlet.

Burner hole or slits on the side

• Remove the burners (on models with standard twin

of the burner may be clogged.

burners) or burner heads and caps (on models with
sealed burners) and clean them with a sewing needle
or twist-tie. Make sure you do not enlarge the holes.
On sealed burner models, check and clean the electrode
area for burned-on food or grease.

Improper burner assembly.

• Make sure the burner parts are installed correctly.

See the Care and cleaning of the range section.

Drip pans (if so equipped)

• Make sure the drip pans are installed correctly.

are not installed correctly.

Pilot(s) is (are) not lit

• See the Light the Surface Burner Pilots section in the

(on standing pilot models).

Installation Instructions.

Burner flames very

Improper air to gas ratio.

• If range is connected to LP gas, contact the person

large or yellow

who installed your range or made the conversion.

Surface burners light

The oven gas shut-off valve

• To check the oven gas shut-off valve on sealed burner

but oven does not

may have accidentally been

models, remove the broiler drawer or kick panel

moved during cleaning or

(see the Care and cleaning of the range section) and

moving.

look for the gas shut-off lever at the back of the range.

• To check the oven gas shut-off valve on standard twin

burner models, raise the cooktop and look for the
gas shut-off lever at the extreme right rear corner.
(Standing pilot models do not have a gas shut-off valve
on the regulator.) Follow the directions in box A or B
that match your regulator type.

Lever is
shown closed.
PULL TO OPEN.

Sealed burner models

Lever is shown closed.
PULL TO OPEN.

Standard twin burner models

Lever is shown closed.
PULL TO OPEN.

Standard twin burner models

A

B

Advertising