Troubleshooting tips, 46 questions? before you call for service – GE EGR3001 User Manual

Page 46

Advertising
background image

46

QUESTIONS?

BEFORE YOU CALL FOR SERVICE…

PROBLEM

POSSIBLE CAUSE

TOP BURNERS DO NOT

• Make sure electrical plug is plugged into a live power outlet.

LIGHT OR DO NOT

• Burner holes on the side or around the top of burner may be clogged. Remove

BURN EVENLY

burners (on models with standard twin burners) or burner heads (on models with
sealed burners) or burner caps on spill-proof models, and clean them with a
sewing needle or twist-tie. Make sure you do not enlarge the holes. On
spill-proof models, check electrode area for burned-on food or grease.

• Make sure the drip pans (on some models) are installed correctly.

BURNER FLAMES VERY

• If range is connected to LP gas, contact the person who installed your range

LARGE OR YELLOW

or made the conversion.

SURFACE BURNERS

• The oven gas shut-off valve may have accidentally been moved during

LIGHT BUT OVEN

cleaning or moving.

DOES NOT

To check the oven gas shut-off valve on standard twin burner models, raise
the cooktop and look for the gas shut-off lever at the extreme right rear corner.
(Standing pilot models do not have a gas shut-off valve on the regulator.)
Follow the directions in box A or B that match your regulator type.

To check the oven gas shut-off valve on sealed burner models, remove
the storage drawer, broiler drawer or kick panel and look for the gas shut-
off lever at the back of the range.
Follow the directions in box A or B that match your regulator type.

Lever shown closed.

PULL TO OPEN.

Lever shown closed.

PULL TO OPEN.

A

B

Standard Twin Burner Models

Standard Twin Burner Models

Sealed Burner Models

Sealed Burner Models

A

B

Lever shown

closed.

PULL

TO OPEN

.

Lever shown
closed. PULL

TO OPEN

.

Advertising