background image

Specification Created 1/03

ZV1050SF – GE Monogram 42" High Performance Island Hood

Dimensions and Specifications (in inches)

Product Dimensions

This vent hood is designed to be used in vented ceiling
mounted installations.

*20" to an 8 ft. ceiling

Using supplied duct cover

*

32" for 9 ft. ceiling.
Using ZX1059SFSS Accessory

*

44" for 10 ft. ceiling
Using ZX10510SFSS Accessory

This vent hood is supplied with a decorative duct cover to
reach 8 ft. ceiling height, or between 7'11" and 8'1".

Duct Cover Accessories

Order Accessory duct covers for 9 ft. and 10 ft. ceilings.

ZX1059SFSS – For 9 ft. ceiling height
This kit includes a decorative duct cover and support frame to
reach a 9 ft. ceiling height.

ZX10510SFSS – For 10 ft. ceiling height
This kit includes a decorative duct cover and support frame to
reach a 10 ft. ceiling height.

Order the accessory at the same time as the vent hood and
have on site before installation begins.

Product Clearances

This vent hood must be installed 25-1/2" min. and 30" max.
above the cooking surface. 30" is recommended for 8 ft.
ceilings. 30" clearance will insure that the duct cover meets
the ceiling. The cooking surface should be at least 36" above
the floor. Installation will be easier if the vent hood is installed
before the cooktop and countertop is installed.

*9 ft. to 10 ft. ceilings may be 25-1/2" to 30" clearance.

*The distance between the cooking surface and the bottom of

the hood must be at least 25-1/2". The 30" recommended
installation height, above the standard 36" countertop, will
insure duct cover fit to the ceiling. For 9 ft. and 10 ft. ceilings,
the hood may be lowered to 25-1/2" over the cooking surface.

IMPORTANT: Clearances may vary due to type of cooking
product and local codes. Check with local inspectors to be
sure standard is applicable.
–When installing the Island Hood above a Monogram

Professional Range or Cooktop, installation clearance must be
at least 30".