GE ZICP360NXLH User Manual

696dia7, Zicp_bf_ref_qs_art, Zicp360nx

Advertising
background image

For answers to your Monogram,

®

GE Profile

or

GE

®

appliance questions, visit our website at

ge.com or call GE Answer Center

®

service,

800.626.2000.

Listed by

Underwriters

Laboratories

Specification Created 6/08

110113

696Dia7

6"

Wall View

Electrical

Area

84-1/2" max

83-1/2" min

Finished

Opening

75" From

Floor to Bottom

of Electrical

Area

10"

5"

3 1/2"

5"

3 1/2"

24" Cutout Depth

35-1/2"

Finished Width

2-5/16"

Note: Icemaker

water connection

is at the front.

Cold Water

Supply

*Shipping height. The

refrigerator can be adjusted

to fit into a cutout that is

83-1/2" min. to 84-1/2" max.

height. Note that the top case

trim at the front is 1/2" higher

and will overlap upper cabinetry

or soffit. Use leveling legs

and wheels for a maximum

1" height adjustment.

25-3/4" Case Depth

84"* from

floor to

top frame

35" Case Width

83-1/2"*

at Rear

28-11/16"

36" Frame to

Frame Width

Depth Including Handles

The Installation Space
The finished cutout width must be 35-1/2".

Product Dimensions

*

Shipping Height:

The refrigerator

can be adjusted

to fit into a cutout

that is 83-1/2" min.

to 84-1/2" max.

height. The top case

trim at the front

is 1/2" higher and

will overlap upper

cabinetry or soffit.

Use leveling legs

and wheels for a

maximum 1" height

adjustment.

The cutout depth must be 24"
The refrigerator will project forward, slightly beyond adjacent
cabinetry, depending on your installation.
The cutout depth beneath a soffit
When installed beneath a soffit, the soffit cannot exceed the
24" installation depth shown. The top case trim overlaps the
bottom of the soffit.
Electrical
A 115V, 60Hz., 15 or 20 amp power supply is required. An
individual properly grounded branch circuit or circuit breaker
is recommended. Install a properly grounded 3-prong
electrical receptacle recessed into the back wall. Electrical
must be located on rear wall as shown.

Note: GFI (ground fault interrupter) is not recommended.
Water Line
The water line can enter the opening through the floor
or back wall. Route GE SmartConnect

Kit or 1/4" O.D.

copper tubing between the cold water line and the water
connection location at the front of the refrigerator. The
tubing must be long enough to extend to the front of the
refrigerator. The installation of an easily accessible shut-off
valve in the water line is required.

605Dia20

25"

Min. to

Wall

130

°

130

° Door Swing

23-7/8"

Behind

Frame

36-3/4"

zicp_bf_ref_qs_art

90

°

90

° Door Swing

5" Min.

to Wall

Door Swing Clearances
The installation must allow for clearances to adjacent walls
or cabinets. These refrigerators are equipped with a 2-
position door stop. The factory-set 130° door swing can be
adjusted to 90° if clearance to adjacent cabinets or walls is
restricted.

Allow 25" minimum clearances for a full 130° door swing.
Allow 15" for pan removal.
• 5" minimum clearance is required when the door swing is

adjusted to 90°. If the 90° door stop position is used, pan
access is maintained, but pan removal is restricted.

Dimensions and Installation Information (in Inches)