Goodman Mfg GKS9 User Manual

Page 36

Advertising
background image

36

GKS9 WIRING DIAGRAM

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

H

IG

H

V

O

LTA

G

E

!

D

IS

CO

NNE

CT

AL

L

PO

WER

BE

F

O

RE

SE

R

V

IC

IN

G

OR

IN

S

T

A

LLI

N

G

TH

IS

UNI

T

.

M

U

LTI

P

L

E

PO

WER

S

O

U

RCE

S

MA

Y

BE

PR

E

S

EN

T

. F

AIL

U

RE

TO

DO

SO

MA

Y

CAU

S

E

PR

O

P

E

R

T

Y

DAM

AG

E

,

P

E

RS

O

NAL

INJ

URY

OR

DE

AT

H

.

R

YL YELLOW
OR ORANGE

PU PURPLE
GN GREEN
BK BLACK

BR BROWN
WH WHITE

BL BLUE
GY

GRAY

RD RED

COLOR CODES:

LOW VOLTAGE (24V)

LOW VOLTAGE FIELD

HI VOLTAGE (115V)

H

I VOLTAGE FIELD

NOTES:

1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.

2

. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.

0140F00236 REV. C

O

R (MED LOW)

BL (MED)

RD (LOW )

GAS VALVE

C2

C

G

W

INTERNAL TO

INTEGRATED CONTROL

JUNCTION

E

QUIPMENT GND

FIELD GND

DIAGNOSTIC
L

ED

2

CIRCUIT

CONNECTOR

H

OT

SURFACE
IGNITER

OVERCURRENT

PROT. DEVICE

I

GNITER

T

H (3)

INTEGRATED
CONTROL MODULE

JUNCTION BOX

L

INE-H

XFMR-H

IN

TE
GRA

T

ED

CO

NTRO

L

MO

DUL

E

IN

TE
GRA

T

ED

CO

NTR

O

L

MOD

U

L

E

G

ND

D

ISCONNECT

L

N

OVERCURRENT PROTECTION DEVICE

RD

BL

BK

4. IF HEATING AND COOLING BLOWER SPEEDS ARE NOT THE SAME, DISCARD JUMPER BEFORE CONNECTING BLOWER LEADS. UNUSED

BLOWER LEADS MUST BE PLACED ON "PARK" TERMINALS OF INTEGRATED CONTROL OR TAPED.

3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL

HAVING A TEMPERATURE RATING OF AT LEAST 105

TERMINAL

S

WITCH (PRESS.)

5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.

P

K PINK

1

15 VAC HOT AND PARK TERMINALS

LINE-H

F

LAME

SE

NSOR

BK

PLUG CONNECTION

FIELD SPLICE

S

WITCH (TEMP.)

OR

24V THERMOSTAT

CONNECTIONS

G

R

G

ND

115 VAC

24 VAC

BLOWER
COMPARTMENT
DOOR SWITCH
(OPEN WHEN
DOOR OPEN)

DOOR
SWITCH

BK

GND

L

N

WH

JUNCTION
BOX

1

O

R

ID BLOWER
PRESSURE
SWITCH

H

EAT-H

GND

W H

RD

WH

GND

BURNER COMPARTMENT

BLOWER COMPARTMENT

NOTE 4

SEE

N
O

C

OOL-H

BK (HI)

BR

B

R

CAPACITOR

Y

L

WH

B

L

PU

RD

OR

PK

BK

WH

WH

BL

OWER

INDUCED DRAFT

MANUAL RESET
A

UXILIARY LIMIT

IN UPFLOW
BLOWER DECK

C

FS

HE

AT

-H

CO

OL

I

GNITER

HOT SURFACE

IND

IGN

BLWR

CIRCULATOR

BLWR

I

D

FLAME SENSOR

115 VAC

T

RANSFORMER

4

0 VA

24 VAC

GND

RO1 (5)

RO2 (11)

HLO (1)

HLI (7)

MVC (9)

GND (8)

TR (6)

OR

WH

WH

BL

YL

OR

RD

GR

BR

PK

PK

W

H

11

5

V

A

C NE

U

T

RA
L

BK

BK

BK

G

Y

2

4

V

T

H

ER

M

O

ST
A

T

C

O

NNEC

T

IO

NS

MICRO

TO

C

G

Y

W

R

2

WH

OR

BL

YL

OR

PK

RD

OR

WH

XF
M

R

-H

TE
R

M

IN

A

L

S

BL

GY

GR

1

2

3

12

11

1

0

9

8

7

6

5

4

°C. USE COPPER CONDUCTORS ONLY.

2

4 VAC

H

UMIDIFIER

24 VAC

HUMIDIFIER

H

UMIDIFIER

P

SO (4)

MV(12)

PS (10)

C

NO

ID BLOWER
PRESSURE

SWITCH

0

C

6

5

4

3

2

1

OFF = CONTROL FAILURE

STEADY ON = NORMAL OPERATION

1 FLASH =

2 FLASHES = PRESSURE SWITCH STUCK CLOSED

3 FLASHES = PRESSURE SWITCH STUCK OPEN

4 FLASHES = OPEN HIGH LIMIT

5 FLASHES = FLAME SENSE WITHOUT GAS VALVE

6 FLASHES =

CONTINUOUS/RAPID FLASHES = REVERSED 115 VA C POLARITY

CONTROL

MODULE

I

NTEGRATED

FUSE

MI

G

Y

GY

M1

GAS

VALVE

C2

TO 115VAC/ 1 Ø /60 HZ POWER SUPPLY WITH

PU

Y

BR

GY

BR

L

INE NE

UT
RA

L

S

NO

C

O

PTIONAL FRONT COVER

PRESSURE SWITCH

C

N
O

OPTIONAL FRONT COVER
PRESSURE SWITCH

Advertising