Auxiliary controls on your Zoneline.

GEAppliances.com

Auxiliary Controls—Aux Set Button

The auxiliary set controls are located behind
the room cabinet, below the control panel.

Remove the room cabinet. See the To Remove
the Room Cabinet
section.

The owner is responsible for ensuring the auxiliary
controls are set to the desired function. There are 9
different modes that can be set using the auxiliary
set button. To change modes, press AUX SET (“AU”
appears on the display). Press the mode button on
the control pad until the first digit in the display
shows the number corresponding to the mode you
are choosing and the correct HEAT/COOL LED is lit.
Press the up or down arrow (shown in the second
digit of the display) to make the mode setting
selection where applicable. Press the AUX SET
button to confirm the selection.

S

a

fe

ty

In

st

ru

c

tio

n

s

O

p

e

ra

tin

g

In

st

ru

c

tio

n

s

C

a

re

a

n

d

C

le

a

n

in

g

T

ro

u

b

le

sh

o

o

tin

g

T

ip

s

C

o

n

su

m

e

r

S

u

p

p

o

rt

Smart Fan—Cooling/Heating

The default setting for Mode 1 is as follows:
Cooling: Continuous (ON)
Heating: Cycle (OFF)

Press MODE until a 1 appears in the first digit of the
display for Smart Fan cool mode. The COOL LED
light on the main control will be on. To change to
heat mode, press MODE again. The HEAT LED light
on the main control will be lit. Press the down arrow
to set the indoor fan to cycle on/off when the unit is
heating or cooling "

." Press the up arrow to set

the indoor fan to run continuously "

." This is

shown in the second digit of the display. Press AUX
SET
to confirm your selection and exit AUX SET
mode, or press MODE to continue setting other
functions.

Auxiliary Set Button

Access Cover

Cooling – Cycle

Heating – Cycle

Cooling – Continuous

Heating – Continuous

MODE 1

HIGH

COOL

LOW

FAN

AUTO

HEAT

HIGH

COOL

LOW

FAN

AUTO

HEAT

HIGH

COOL

LOW

FAN

AUTO

HEAT

HIGH

COOL

LOW

FAN

AUTO

HEAT

Load Shedding (Central Desk Control)

The default setting for Mode 2 is OFF.

This feature is active only if the unit is connected to
a CDC and the CDC has control. Press MODE until a
2 appears in the first digit of the display for Load
Shedding
mode. Press the down arrow for OFF "

"

or the up arrow for ON "

." This is shown in the

second digit of the display. When this mode is on,
only the indoor fan can be turned ON or OFF with
the unit controls. When this mode is off, all
operation is disabled except Heat/Freeze Sentinel
(Mode 3). Press AUX SET to confirm your selection
and exit AUX SET mode, or press MODE to continue
setting other functions.

Load

Shedding

OFF

Load

Shedding

ON

MODE 2

5