14

Pipeline HD.2 Series SATA Product Manual, Rev. A

2.9.5

Shock

All shock specifications assume that the drive is mounted securely with the input shock applied at the drive
mounting screws. Shock may be applied in the X, Y or Z axis.

2.9.5.1

Operating shock

The drives comply with the performance levels specified in this document when subjected to a maximum oper-
ating shock of 70 Gs based on half-sine shock pulses of 2 msec. Shocks should not be repeated more than
two times per second.

2.9.5.2

Nonoperating shock

The nonoperating shock level that the drive can experience without incurring physical damage or degradation
in performance when subsequently put into operation is 350 Gs based on a nonrepetitive half-sine shock pulse
of 2 msec duration.

2.9.6

Vibration

All vibration specifications assume that the drive is mounted securely with the input vibration applied at the
drive mounting screws. Vibration may be applied in the X, Y or Z axis.

2.9.6.1

Operating vibration

The maximum vibration levels that the drive may experience while meeting the performance standards speci-
fied in this document are specified below

2.9.6.2

Nonoperating vibration

The maximum nonoperating vibration levels that the drive may experience without incurring physical damage
or degradation in performance when subsequently put into operation are specified below.

5–350 Hz

0.50 Gs

350–500 Hz

0.25 Gs

5–350 Hz

5.0 Gs

350–500 Hz

1.0 Gs

Advertising