13

Troubleshooting and Diagnostics

13-13

Troubleshooting FC/SCSI Tape Pipelining (Device Extension)

V002

Basic hardware (serial port, PCI, network)

initialization

failed

V003

Kernel configuration failed

V004

Instruction cache enabling failed

V005

Kernel root task creation failed

V007

Memory pool initialization failed

V008

MMU initialization failed

V009

System timer initialization failed

V010

Console initialization failed

V011

Filesystem initialization failed

V012

Real-time clock initialization failed

V013

I2C initialization failed

V014

Disk initialization failed

V015

Network initialization failed

V016

Misc. failures

V017

System symbol table creation failed

V018

Misc library initialization failed

V019

Script running failure

V020

Shell initialization failure

VXOK

Kernel ok

V020-V027

Network protocol initialization failed

V028-V030

unused

V030

Can't load network config info from NVRAM or

BOOTP failure.
V031-V037

Network stack setup failed

V038

unused

VXOK

Kernel ok

Troubleshooting FC/SCSI Tape Pipelining (Device Extension)

The following section provides basic troubleshooting steps for your
UltraNet Edge 3000’s FC/SCSI Tape Pipelining (Device Extension)
network.

This section is not intended to be an exhaustive troubleshooting
guide for FC/SCSI Tape Pipelining, also called Device Extension, but
provides basic steps to provide visibility from the tape device(s) to
the server. This section assumes the user has some SCSI experience.

NOTE:

Tuning Veritas NetBackup or Tivoli Storage Manager may result in

higher throughput through the UltraNet Edge 3000. If you need assistance
with application tuning, contact McDATA Advanced Services.