Diagnostics, Diagnostics -16 – McDATA ULTRANETTM EDGE STORAGE ROUTER 3000 User Manual

Page 328

Advertising
background image

13

13-16

McDATA UltraNet Edge 3000 User Guide

Diagnostics

ttag wwnPurg 2 x perm

command. Issuing the

ttag

wwnDisp

command will display the permanently purged

entries in the table as purged perm in that entry.

6. Did the UltraNet Edge 3000 dynamically discover all of the

devices?

a. The UltraNet Edge 3000 will not dynamically discover devices

beyond what is configured in the Discover LUN Count field
(the default is 8). Use UltraNet ConfigManager to statically
configure LUN s out of this range in this situation. See the
“Static Mapping the LUNs and Filtering the Source WWN”
section in Chapter 9. The Discover LUN Count field is
configured in step 10 of this section.

7. Are multiple devices connected through a FC-SCSI bridge and

you don’t want the UltraNet Edge 3000 to automatically map all
the devices?

a. The FC-SCSI bridge has one WWN and the devices are

attached to LUNs on that WWN. The

ttag

wwnPurg

command

will purge single entries from the table, however, the

ttag

wwnRel

command will only allow a release of a WWN which

will cause the UltraNet Edge 3000 to re-discover all the
devices attached to that WWN. See the “Static Mapping the
LUNs and Filtering the Source WWN” section in Chapter 9.

NOTE:

If a configuration has already been delivered, it is acceptable to open

that configuration in UltraNet ConfigManager (UCM) and statically
configure the entry in the next available position after the last discovered
entry. From the UltraNet Edge 3000, issue the ttag luns command to list
the current LUN map. After delivering the UCM config and the Edge resets
itself, verify the new LUN map by issuing the ttag luns command.

Diagnostics

The UltraNet Edge 3000 has a number of diagnostic programs used to
validate hardware functionality. When you are experiencing
problems, use these diagnostic programs to ensure that the UltraNet
Edge 3000 is working properly.

Access to the UltraNet Edge 3000 diagnostic programs is made
through either a standalone serial connection to the UltraNet Edge
3000 or by telnetting via the Ethernet maintenance interface to the

Advertising