Minimum requirements for crc, Fibre channel mtu batching – McDATA ULTRANETTM EDGE STORAGE ROUTER 3000 User Manual

Page 68

Advertising
background image

3

3-14

McDATA UltraNet Edge 3000 User Guide

Minimum Requirements for CRC

An Edge configured for FC/SCSI Tape Pipelining has added
functionality when an End-to-End CRC error is detected. If an
End-to-End CRC error occurs while Write Pipelining is active, the
tape device will be repositioned to the last successful write and the
Write I/Os active in the pipe at the time of the CRC error will be
retried one time only. If the CRC retry is not successful bad ending
status is returned.

Minimum Requirements for CRC

The minimum hardware levels for both Frame Level and End to End CRC
are provided in the UltraNet Edge Storage Router - 3000 Series Release
Notes
(part number 30200581).

Fibre Channel MTU Batching

MTU Batching is available on the UltraNet Edge 3000 FCBB Fibre
Channel card.

The MTU Batching size defines the MTU for the batch of backbone
frames that are collected and transmitted as one packet across the
network. The batching size is set to 16000, this means a maximum of
16 frames will be batched.

MTU Batching is available for E_port and F_port configurations on
the FCBB Fibre Channel card.

The default is On and set for 16000. To disable this option, see the

Configuring the Internal McDATA Fibre Channel Switch Interface

section

in

Appendix D, Advanced UCM Configurations

.