APPENDIX A: ACHERON 80 AND ACHERON 100 SPECIFICATIONS

Acheron 80 and Acheron 100 Specifications

ACOUSTICAL

Operating Frequency Range

37 Hz – 18 kHz
Note: Recommended maximum operating frequency range. Response depends on loading
conditions and room acoustics.

Frequency Response

38 Hz – 17 kHz ±4 dB
Note: Measured free field with 1/3 octave frequency resolution at 4 meters.

Phase Response

700 Hz to 17 kHz ±30°

Maximum Peak SPL

139 dB
Note: Measured free field with music referred to 1 meter.

Dynamic Range

>110 dB

Coverage

Acheron 80: 80° horizontal by 50° vertical
Acheron 100: 100° horizontal by 50° vertical

Crossover

580 Hz
Note: At this frequency, both transducers produce equal sound pressure levels.

TRANSDUCERS

Low Frequency

One high-power 15” cone driver with neodymium magnet
Nominal impedance: 4

Ω

Voice coil size: 4”
Power-handling capability: 1200 W (AES)
Note: Power handling measured using AES standards: transducer driven continuously for two
hours with a band limited noise signal having a 6 dB peak-average ratio.

High Frequency

One 4” compression driver
Nominal impedance: 8

Ω

Voice coil size: 4”
Diaphragm size: 4”
Exit size: 1.5”
Power-handling capability: 250 W (AES)
Note: Power handling measured using AES standards: transducer driven continuously for two
hours with a band limited noise signal having a 6 dB peak-average ratio.

AUDIO INPUT

Type

Differential, electronically balanced

Maximum Common Mode Range

±15 V DC, clamped to earth for voltage transient protection

Connectors

Female XLR input with male XLR loop output

Input Impedance

10 k

Ω differential between pins 2 and 3

Wiring

Pin 1: Chassis/earth through 220 k

Ω, 1000 pF, 15 V clamp network to provide virtual ground lift

at audio frequencies
Pin 2: Signal +
Pin 3: Signal –
Case: Earth ground and chassis

DC Blocking

None on input, DC block through signal processing

CMRR

>50 dB, typically 80 dB (50 Hz – 500 Hz)

RF Filter

Common mode: 425 kHz

Differential mode: 142 kHz

TIM Filter

<80 kHz, integral to signal processing