J/B/G-0600 COMPRESSOR REPLACEMENT

Installation Instructions

NOTE: THIS REPLACEMENT IS ONLY FOR THE J, B, AND G-SERIES ICE MACHINES. START AND RUN

COMPONENT CHANGES VARY WITH THE TYPE OF MACHINE. FOR J-SERIES MACHINES ONLY, THE
RUN CAPACITOR NEEDS TO BE REPLACED WITH THE ONE INCLUDED IN THE KIT. B AND G-SERIES
MACHINES NEED ALL OF THE START AND RUN COMPONENTS REPLACED WITH THE ONES
INCLUDED IN THE KIT.

1. Disconnect power to the ice machine at the electrical

disconnect (moving the toggle switch to the off
position will not disconnect line voltage).

2. Remove panels (top, front, left and right sides).
3. Recover refrigerant from ice machine.
4. Remove right side corner post (when facing the front

of the machine) and back panel.


5. Remove wiring from compressor terminals.


















6. Unsweat suction line at compressor port. Unsweat

discharge and process lines at the T fitting and
swage joint (or after “T” fitting, if remote)
respectively.

NOTE:

IF REPLACING COMPRESSOR IN A
REMOTE ICE MACHINE, BE SURE TO
UNSWEAT THE CONNECTION BETWEEN
THE HPR VALVE AND THE PROCESS
TUBING AT THE “T” FITTING.

7. Remove compressor from machine. Make sure to

crimp and braze shut ports to compressor.

8. Insert new compressor into the machine, as shown.