Appendix j - rs-232c interface specifications, Appendix j – Multitech MT1432BA User Manual

Page 156

Advertising
background image

156

MultiModemBA User Guide

Appendix J - RS-232C Interface Specifications

The modem's RS-232C interface circuits have been designed to meet the electrical specifications
given in EIA (Electronic Industries Association) RS-232C standards. All signals generated by the
modem are approximately 10 volts when measured across a load of 3000 ohms or greater. The
receiving circuits of the modem will accept signals in the 3 to 25 volt range. The voltage thresholds
are:

Negative = voltage more negative than 3 volts with respect to signal ground

Positive = voltage more positive than +3 volts with respect to signal ground

SIGNAL INFORMATION:

NEGATIVE

POSITIVE

Binary State

One

Zero

Signal Condition

Mark

Space

Control and Timing Function

Off

On

The input impedances of all modem circuits which accept signals from the data processing terminal
or CPU equipment have DC resistances of 4.7K. For more specific details, consult the EIA RS-232C
standard itself.

The following chart lists the EIA RS-232C interface pins and circuits present on the modem's
RS232C Interface connector. All other pins are unused.

Pin

Designation

eia

CCITT

signal

Function

Assignment

circuit

circuit

source

1

PG

--

101

--

Protective Ground

2

SD

BA

103

DTE

Transmitted Data

3

RD

BB

104

DCE

Received Data

4

RTS

CA

105

DTE

Request to Send

5

CTS

CB

106

DCE

Clear to Send

6

DSR

CC

107

DCE

Data Set Ready

7

SG

AB

102

--

Signal Ground

8

CD

CF

109

DCE

Carrier Detect

9**

+v

+v

--

DCE

Test Voltage

12

HS

--

--

DCE

High Speed

15***

TC

DB

114

DCE

Transmit Clock

17***

RC

DD

115

DCE

Receive Clock

20

TR****

CD

108/2

DTE

Terminal Ready

22

RI

CE

125

DCE

Ring Indicator

24

XTC

DA

113

DTE

External Transmit Clock

25

OOS

CN

142

DTE

Terminal Busy

** Pin 9 need not be present in your RS-232C cable

*** Pins 15 and 17 are necessary only for synchronous operation

**** Also known as DTR (Data Terminal Ready)

The computer or terminal should be supplied with a cable terminated with a Cinch DB-25P (or
equivalent) connector mounted in a Cinch DB-51226-1 (or equivalent) hood assembly as specified by
the EIA RS-232C standard.