2 remote configuration procedures, Remote configuration procedures – Multitech MT1432BA User Manual

Page 92

Advertising
background image

92

MultiModemBA User Guide

7.3.2

Remote Configuration Procedures

The procedures for using the Remote Configuration features are the same whether or not a call
originates from the remote modem. Once the modem is on-line, perform the procedures in Table 7-4.

Table 7-4 Remote Configuration Operation Procedures

Step

Procedure

1.

Remote Escape Configuration requires %%%AT<CR> to be sent if the default value in S-
Register S13 has not been changed.

The modem responds with:

1. - DATA Mode
2. - COMMAND Mode

2.

You then select 1 or 2. With 1, the modem goes back into data mode and with 2, the modem
responds with the following:

Password>

3.

Enter your Setup Password, and if the code is correct the modem responds with:

OK

You can now use any AT commands of the modem being remotely configured as if they were
being entered locally. You cannot change the setup of the LOGIN Password until you enter the
proper LOGIN Password.

4.

When you are done entering AT commands and you want to exit, type AT0 and hit RETURN.
The modem responds with:

1. DATA Mode
2. COMMAND Mode

5.

Enter a 1 to go back on-line with your computer, or enter 2 and the correct password to talk to
your modem.