Installation Instructions

ELECTRICAL CONNECTIONS

Electrical Requirements

120-volt, 60 Hertz, properly grounded dedicated circuit
protected by a 15-amp or 20-amp circuit breaker or
time delay fuse.

Extension Cord Cautions

Because of potential safety hazards associated
with certain conditions, we strongly recommend against
the use of an extension cord. However, if you still elect
to use an extension cord, it is absolutely necessary that
it be a UL-listed, 3-wire grounding-type appliance
extension cord and that the current carrying rating of
the cord in amperes be equivalent to, or greater than,
the circuit rating.

Grounding

IMPORTANT—(Please read carefully)

FOR PERSONAL SAFETY, THIS APPLIANCE MUST
BE PROPERLY GROUNDED.

The power cord of this appliance is equipped with a
three-prong (grounding) plug which mates with a
standard three-prong grounding wall receptacle to
minimize the possibility of electric shock hazard from
this appliance.

The customer should have the wall receptacle and
circuit checked by a qualified electrician to make sure
the receptacle is properly grounded.

Where a standard two-prong wall receptacle is
encountered, it is the personal responsibility and
obligation of the customer to have it replaced with a
properly grounded three-prong wall receptacle.
DO NOT, UNDER ANY CIRCUMSTANCES,
CUT OR REMOVE THE THIRD (GROUND) PRONG
FROM THE POWER CORD.
A word about GFCI’s – GFCI’s are not required or
recommended for gas range receptacles.

Ground Fault Circuit Interrupters (GFCI’s) are
devices that sense leakage of current in a circuit and
automatically switch off power when a threshold
leakage level is detected. These devices must be
manually reset by the consumer. The National Electrical
Code requires the use of GFCI’s in kitchen receptacles
installed to serve countertop surfaces. Performance of
the range will not be affected if operated on a GFCI-
protected circuit but occasional nuisance tripping of
the GFCI breaker is possible.

Preferred Method

Ensure proper ground
exists before use

ELECTRICAL CONNECTIONS

(CONT.)

3

A. Usage Situations where Appliance Power Cord will

be Disconnected Infrequently.

An adapter may be used only on a 15-amp circuit.
Do not use an adapter on a 20-amp circuit. Where
local codes permit, a TEMPORARY CONNECTION
may be made to a properly grounded two-prong wall
receptacle by the use of a UL-listed adapter, available
at most hardware stores. The larger slot in the adapter
must be aligned with the larger slot in the wall
receptacle to provide proper polarity in the
connection of the power cord.

When disconnecting the power cord from the adapter,
always hold the adapter with one hand. If this is not
done, the adapter ground terminal is very likely to
break with repeated use. Should this happen, DO
NOT USE

the appliance until a proper ground

has again been established.

CAUTION:

Attaching the adapter

ground terminal to the wall receptacle cover
screw does not ground the appliance unless
the cover screw is metal, and not insulated,
and the wall receptacle is grounded through
the house wiring. The customer should have
the circuit checked by a qualified electrician
to make sure the receptacle is properly
grounded.

Temporary Method

Ensure proper
ground and firm
connection before
use

(Adapter plugs not permitted in Canada)

Align large prongs/slots

3