For setting up the system, the 485ADP can be connected to the following PCs.

PC series

FX

0N

FX , FX

2C

PC version

Ver. 1.20 or later

Ver. 3.30 or later

Remarks

Exclusive protocol format 1 and format 4 are supported.

Exclusive protocol format 1 and format 4 are supported.

FX

0N

-485ADP

FX-485ADP

As for exclusive protocol formats (1, 4) , see the 485PC-IF manual.

For connection with the PC, connect the serial port provided at the left side facing the PC basic unit and the
extension cable of the 485ADP. It must be noted however that only one special adapter (FX-8AV, FX-232ADP,
etc.) such as 485ADP can be connected to the PC.

In the case of FX-485ADP

In the case of FX

0N

-485ADP

F X - 4 8 5 A D P

M I T S U B I S H I

24G

24+

FG

RD

A

RD

B

SD

A

SD

B

LI

N

K

SG

2

WIRING

1.3 Applicable PCs

1.4 Connection with PC

The connecting method with the 485PC-IF is available in two-pair wiring and one-pair wiring, which may be
used as follows. As for connection of the 485PC-IF and computer, see the 485PC-IF manual.

Two-pair wiring is required when :

The RS-422 device is incorporated in the system configuration.

A high speed response is required (message waiting time is desired to be less than 70 ms).

The on-demand function is used (however, the system configuration must be 1 : 1).

Adding to a system already using two-pair wiring.

* See the 485PC-IF manual.

One-pair wiring is required when :

Adding to a system already using one-pair wiring.

The system configuration is standardized to RS-485 devices, and two-pair wiring is not needed.

*