16

DiamondMax 21 PATA Product Manual, Rev. B

2.9

Environmental specifications

2.9.1

Ambient temperature

Ambient temperature is defined as the temperature of the environment immediately surrounding the drive.
Actual drive case temperature should not exceed

69°C (156°F) within the operating ambient conditions. Rec-

ommended measurement locations are shown in See Figure 6 on page 27.

Above 1,000 feet (305 meters), the maximum temperature is derated linearly to 112°F (44°C) at 10,000 feet
(3,048 meters).

2.9.2

Temperature gradient

2.9.3

Humidity

2.9.3.1

Relative humidity

2.9.3.2

Wet bulb temperature

2.9.4

Altitude

Operating:

5° to 60°C (41° to 140°F)

Nonoperating:

–40° to 70°C (–40° to 158°F)

Operating:

20°C per hour (68°F per hour max), without condensation

Nonoperating:

30°C per hour (86°F per hour max)

Operating:

5% to 90% noncondensing (30% per hour max)

Nonoperating:

5% to 95% noncondensing (30% per hour max)

Operating:

37.7°C (99.9°F max)

Nonoperating:

37.7°C (99.9°F max) 320 - 200GB models
40.0°C (104°F max) 160 - 80GB models

Operating:

–60.96 m to 3,048 m (–200 ft. to 10,000+ ft.)

Nonoperating:

–60.96 m to 12,192 m (–200 ft. to 40,000+ ft.)