OS77 Series Single Set Point Switch

Installation and Operation Instructions

OS-98001N

Effective 04-98

Section 20

00-02-0303

Description

The OS77 Series single set point speed switch is a compact, all-electronic,
speed sensing module. It is field adjustable and can be panel mounted via its
trip set point potentiometer.
Standard OS77 models provide a transistor output when tripped. Models with a
relay output are available.
The OS77 is used for protecting the engine from excessive or insufficient oper-
ating speeds. As the engine speed reaches the adjustable set point setting, the
OS77 will cause the engine to shutdown.
Models are available with Normally Open or Normally Closed circuit and
available recrank feature which inhibits starter re-engagement until the engine
speed is near zero RPM.

Specifications

Power Supply: Voltage: 7-28 VDC.

Maximum Current: 100 mA.

Frequency Signal:

Voltage, Magnetic Pickup Signal Models

Minimum: 1.2 Vrms

Maximum: 30 Vrms

Voltage, Distributor Ignition Models

Minimum: 6 Vrms

Maximum: 30 Vrms

Maximum Current, Magnetic Pickup Signal Models: 0.12 mA
Maximum Current, Distributor Ignition Models: 0.12 mA
Adjustment Range, Magnetic Pickup Signal Models: 1000-10,000 Hz
Adjustment Range, Distributor Ignition Models: 40-400 Hz
Reset Differential, Magnetic Pickup Signal Models

Non-recrank model: 10 Hz Differential

Recrank model: dropout 54 Hz

Reset Differential, Distributor Ignition Models

Non-recrank model: 10 Hz Differential

Recrank model: dropout 2.4 Hz

Output:

Transistor Sink to Ground Resistive Load: 2 A, 28 VDC

Relay Output Models: 5 A, 250 VAC

Adjustment: 270°–turn potentiometer
Temperature Range: -13° to 185°F (-25° to 85°C)

OS77 Module Dimensions

Please read the following information before installing

.

A visual inspection of this product for damage during shipping is recommended

before mounting. It is your responsibility to have a qualified person install this unit and make sure it conforms to NEC and local codes.

GENERAL INFORMATION

Installation Accessories

Hardware tools and optional equipment needed to install the OS77:

Tools as needed for system mounting such as drill and screw driver

18 AWG wire for extension and hook up

Wire termination tools and ring or spade wire termination.

Voltmeter or test lamp for set up and adjustments.

®

FRANK W.

MFR.

WARNING

BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT

Disconnect all electrical power to the machine.

Make sure the machine cannot operate during installation.

Follow all safety warnings of the machine manufacturer.

Read and follow all installation instructions.

OS77 Series

1

5

2

3

4

2-1/2 in.

(64 mm)

2-3/8 in.

(60 mm)

2-1/8 in.

(54 mm)

Panel

Mounting
Hardware

Potentiometer

Locknut

Speed Adj.

Potentiometer

Speed Adj.

Potentiometer

Polycarbonate
enclosure

Terminal #5 used for
Relay output models

Positioning
post

Mounting Instructions

The OS77 module is designed to be mounted in a flat panel.

1.

Drill the mounting holes as shown on the template included with the packing.

2.

Insert the module from the back side of the panel (refer to schematic above).

3.

Secure the OS77 module using the mounting hardware included.

Mounting Schematic

Advertising