METRObility Optical Systems ACPS-17HS User Manual

Radiance r5000 power supply, Installation and user guide, Models: acps-17hs / dcps-17hs

Advertising
background image

Installation and User Guide

Models: ACPS-17HS / DCPS-17HS

Radiance

R5000 Power Supply

25 Manchester Street, Merrimack, NH 03054 USA

tel: 603-880-1833 • fax: 603-594-2887

www.metrobility.com

5660-000024 B

8/01

Technical Specifications

Input Power
ACPS-17HS ___________________ 100-120/200-240V AC

___________________________ 50-60Hz, 2A

DCPS-17HS __________________________ 48V DC, 4.9A

Weight
ACPS-17HS ________________________________ 3.25 lb
DCPS-17HS ___________________________________ 3 lb

Environmental
Operating Temperature _____________________ 0º to 50º C
Storage Temperature _____________________ -30º to 70º C
Relative Humidity ___________ 5% to 95% non-condensing
Dimensions ______________________ 7.5"L x 7"W x 3.5"H

___________ (19.1cm L x 17.8cm W x 8.9cm H)

The information contained in this document is assumed to be correct and
current. The manufacturer is not responsible for errors or omissions and
reserves the right to change specifications at any time without notice.

This publication is protected by the copyright laws of the United States
and other countries, with all rights reserved. No part of this publication
may be reproduced, stored in a retrieval system, translated, transcribed,
or transmitted, in any form, or by any means manual, electric, electronic,
electromagnetic, mechanical, chemical, optical or otherwise, without prior
explicit written permission of METRObility Optical Systems, Inc.

© 2001 METRObility Optical Systems, Inc.

All rights reserved. Printed in USA.

RISK OF ELECTRIC
SHOCK, DO NOT OPEN

FACTORY DEFAULT

SETTING 115V

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES,
OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE,
AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.

AC IN

100-120 /
200-240V
50-60Hz,

2A

CAUTION

WARNING

PWR

ACPS-17HS

DISCONNECT ALL POWER

SOURCES BEFORE SERVICING

I.T.E.

E116552

C

LISTED

US

DC IN 48V, 4.9A

RISK OF ELECTRIC
SHOCK, DO NOT OPEN

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES,
OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE,
AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.

CAUTION

PWR

DCPS-17HS

DISCONNECT ALL POWER

SOURCES BEFORE SERVICING

I.T.E.

E116552

C

LISTED

US

Made in

USA

_________________
PRODUCT SERVICE

_________________
PRODUCT SERVICE

Operating Features of the Power Supply

The ACPS-17HS and DCPS-17HS load-sharing power sup-
plies are designed for AC and DC power sources, respec-
tively. Both power supplies are field-replaceable.

When two power supplies are installed in the Radiance
R5000 Central Service Platform, they operate in tandem and
share the load. If the power source to one of the supplies fails
or is removed, the other power supply automatically provides
the entire power load to the platform. This setup provides
both the platform and the network with uninterrupted service.
It also decreases the demand placed upon an individual
power supply, thus prolonging its life.

When the power (PWR) LED on the front panel of the power
supply is lit, it indicates that the power supply is turned on,
connected to an active power source, and providing power to
the platform’s backplane. Because they are load-sharing,
when two power supplies are installed and active in a single
platform, the LEDs on both supplies are lit simultaneously.

An optional display card is available for vis-
ible verification of operating status from the
front of the platform. The R500-D, which
must be installed in slot 16 or 17, provides
two LEDs labeled A and B. When lit, these
LEDs indicate that their corresponding
power supplies are installed properly, con-
nected to an active power source, turned on,
and providing power to the platform’s
backplane. When two power supplies are in-
stalled and active in a single platform, both
LEDs are lit simultaneously.

R500-D

Front Panel

Display Card