Revision 4

Front Panel Operation

MN/CDM570L.IOM

6–17

(CONFIG, TX, PWR, MODE) AUPC

Select either Target EbNo, Max-Range, Alarm or Demod-Unlock using the

arrow keys. The user should then press ENTER.

(CONFIG, TX, PWR, MODE, AUPC) TARGET EbNo

Edit the target Eb/No of the remote demod, using the

◄ ► and

▲ ▼

arrow

keys. Default value is 3.0 dB, and upper limit is 9.9 dB. The user should then
press ENTER.

(CONFIG, TX, PWR, MODE, AUPC) MAX RANGE

Edit the maximum permitted increase in power level (when in AUPC mode),
using the ▲ ▼ arrow keys. Default value is 1dB, and upper limit is 9 dB. Then
press ENTER.

(CONFIG, TX, PWR, MODE, AUPC) ALARM

Select the action that will occur if the AUPC causes the maximum output power

level to be reached, either None or TxAlarm. Then press ENTER.

(CONFIG, TX, PWR, MODE, AUPC) DEMOD-UNLOCK


Select the action that will occur if the remote demod is unlocked. The choices
are: Nom-Pwr (Nominal Power), where the output level will revert to the
nominal power level set under Manual, or Max-Pwr, (Maximum Power), where
the output level will change to the maximum permitted. The user should then
press ENTER.

Target-Eb/No Max-Range
Alarm DemodUnlock (

◄ ►)

Remote Demod - Target
Min Eb/No:9.9dB (

◄ ►,▲ ▼)

Maximum-permitted Power
increase: 1dB (

▲ ▼,ENT)

Action when max Tx Power
reached: None TxAlarm

◄ ►

Action when Remote Demod
unlocks: Nom-Pwr Max-Pwr

Advertising