Mocomtech CDM-570 User Manual

Page 162

Advertising
background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 4

Front Panel Operation

MN/CDM570L.IOM

6–38

If Upper is selected, the following sub-menu is displayed:

Edit BUC Current Alarm Upper limit. This is accomplished by selecting
the digit to be edited, using the

◄ ►

arrow keys. The value of the digit is

then changed using the

▲ ▼

arrow keys. The user should then press

ENTER. The range of current is 500 to 4000 mA.


If Lower is selected, the following sub-menu is displayed:

Edit BUC Current Alarm Lower limit. This is accomplished by selecting
the digit to be edited, using

◄ ►

arrow keys. The value of the digit is

then changed using

▲ ▼

arrow keys. The user should then press

ENTER. The range of current is 0 to 3000 mA.

(CONFIG, ODU, BUC) LO

If LO is selected, the following sub-menu is displayed:

Edit the value of the BUC LO frequency. This is accomplished by selecting the
digit to be edited, using the

◄ ►

arrow keys. The value of the digit is then

changed using the

▲ ▼

arrow keys. The user should then press ENTER. The

valid range is from 3000 to 65000 MHz.

Note this value is used to display the RF frequency of the modem/BUC
combination. If a value of 00000 is entered here (the default), then no RF
frequency will be displayed on the CONFIG, Tx, Tx Freq menu.

BUC Current Alarm Upper
Limit:1200mA (

◄ ►,▲ ▼,ENT)

BUC Current Alarm Lower
Limit:1200mA (

◄ ►,▲ ▼,ENT)

BUC LO Frequency:
12000 MHz (

◄ ►,▲ ▼,ENTER)