Monit, stats) clear, Monit, stats) configure – Mocomtech CDM-570 User Manual

Page 171

Advertising
background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 4

Front Panel Operation

MN/CDM570L.IOM

6–47

If the measured values are greater than, or equal to 16.0 dB, the display will show
16.0 dB.

If AUPC is not enabled, the values of maximum and average TPLI will both
show ‘Off'.

Examples:
08.0, 13.5, 2.5, 1.8 means:
Minimum Eb/No observed in the measurement interval = 8.0 dB
Average Eb/No observed in the measurement interval = 13.5 dB
Maximum TPLI observed in the measurement interval = 2.5 dB
Average TPLI observed in the measurement interval = 1.8 dB

Loss, 04.5, Off, Off means:
There was a loss of demod lock during the measurement interval
Average Eb/No observed in the measurement interval = 4.5 dB
Maximum TPLI observed in the measurement interval = AUPC disabled
Average TPLI observed in the measurement interval = AUPC disabled

(MONIT, STATS) CLEAR

If the user selects Clear-All, the following screen is displayed:


If the user selects Yes, the Statistics log is cleared, and the user is taken directly
back to the previous menu.

(MONIT, STATS) CONFIGURE

If the users selects Configure, the following sub-menu is displayed:


The user is prompted to enter the logging interval (the period of time over which
the statistics will be measured), using the

▲ ▼

arrow keys, then press ENTER.

The user can choose Disabled, 10, 20, 30, 40, 50, 60, 70, 80, or 90 minutes.

Stats Logging Interval:
Disabled (

▲ ▼,ENTER)

Stats Logging Interval:
30 minutes (

▲ ▼,ENTER)

Clear all Stored Stats?
No Yes (

▲ ▼, ENTER)