MN/CDM570L.AA4

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Header
Compression
Refresh rate –
UDP

HRU=

3 bytes

Command or Query.
Header compression refresh rate, 1 to 600
Resolution=1 packet

Refresh rate for UDP only stream.

Example: HRU =50
Restrictions: 570 only

HRU =
HRU!

HRU?

HRU =xxx
(see description of
arguments)

Header
Compression
Refresh rate –
All Others

HRA=

3 bytes

Command or Query.
Header compression refresh rate, 1 to 600
Resolution=1 packet

Refresh rate for all other streams.

Example: HRU =50
Restrictions: 570 only

HRA =
HRA!

HRA?

HRA =xxx
(see description of
arguments)

Payload
Compression
Refresh rate

PRA=

3 bytes

Command or Query.
Payload compression refresh rate, 1 to 600
Resolution=1 packet

Refresh rate for all other streams.

Example: PRU =50
Restrictions: 570 only

PRA =
PRA!

PRA?

PRA =xxx
(see description of
arguments)

Telnet timeout

TET=

2 bytes

Command or Query.
Telnet log in timeout, 1 to 60
Resolution=1 minute
Inactivity timeout on cli menu screen.
Example: <1/TET=50

TET =
TET!

TET?

TET =xx
(see description of
arguments)

Administrator
UserName

ADU=

11 bytes
No spaces
allowed.

Command or Query.
Change the administrator username, where:
Example: ADU=comtech
To get the new user name effective, ADP must be issued
Immediately after ADU. Then query ADU? to see the new.

ADU =
ADU!

ADU?

ADU =xxxxxxxxxxx
(see description of
arguments)

Advertising