Mocomtech CDM-570 User Manual

Page 241

Advertising
background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 4

Serial Remote Control

MN/CDM570L.IOM

13–7

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Unit
Interface
Type

ITF=

1 byte, value
of 0 through 8

Command or Query.
Terrestrial interface type, where:
0=EIA-422/EIA530 DCE
1=V.35 DCE
2=EIA-232 (sync).
3= G.703 T1 AMI (forces Rx and Tx data rates to 1544 kbps)
4= G.703 T1 B8ZS (forces Rx and Tx data rates to 1544 kbps)
5= G.703 E1 Unbal AMI (forces Rx and Tx rates to 2048 kbps)
6= G.703 E1 Unbal HDB3 (forces Rx and Tx rates to

2048 kbps)

7= G.703 E1 Bal AMI (forces Rx and Tx rates to 2048 kbps)
8= G.703 E1 Bal HDB3 (forces Rx and Tx rates to 2048 kbps)
9 = IP Interface
All other codes invalid. Example: ITF=2 (V.35)

ITF=
ITF?
ITF*
ITF#
ITF+

ITF?

ITF =x
(see description of
arguments)

T1 Line
Build-Out

LBO=

1 byte, value
of 0 thru 4

Command or Query.
Valid only for T1 interface, where
0 = 0-133 feet
1 = 133-266 feet
2 = 266-399 feet
3 = 399-533 feet
4 = 533-655 feet

Example: LBO=2
(In all other modes other thanT1, this is a don’t care.)

LBO=
LBO?
LBO *
LBO #

LBO?

LBO=x
(see description of
arguments)

Unit Framing
Mode

FRM=

1 byte, value
of 0 or 1

Command or Query.
Unit operating mode, where
0=Unframed
1= EDMAC Framing
2= EDMAC-2 Framing

Example: FRM=1 (which is framed)

FRM=
FRM?
FRM*
FRM#
FRM+

FRM?

FRM=x
(see description of
arguments)

Priority System = ITF (Highest priority), FRM, TFT, TMD, TCR, and TDR (Lowest Priority), indicated by shading. Any change to a higher
priority parameter can override any of the parameters of lower priority.