Mocomtech CDM-570 User Manual

Page 244

Advertising
background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 4

Serial Remote Control

MN/CDM570L.IOM

13–10

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

AUPC Enable

AUP=

1 byte, value
of 0 or 1

Command or Query.
AUPC mode enable/disable, where:
0=Disabled
1=Enabled
Example: AUP=1
Note: EDMAC framing must be selected for the AUPC feature to
work.

AUP=
AUP?
AUP*
AUP#

AUP?

AUP=x
(see description of
arguments)

AUPC
Parameters

APP=

6 bytes

Command or Query.
Defines AUPC operating parameters. Has the form abc.cd, where:
a=Defines action on max. power condition.
(0=do nothing, 1=generate Tx alarm)
b=Defines action on remote demod unlock.
(0=go to nominal power, 1=go to max power)
c=target Eb/No value, for remote demod, from 0.0 to 9.9 dB
d =Max increase in Tx Power permitted, from 0 to 9 dB

Example: APP=015.67 (Sets no alarm, max power, 5.6 dB target
and 7 dB power increase.)
(Command not valid in Manual mode)

APP=
APP?
APP*
APP#

APP? APP=abc.cd

(see description of
arguments)

Remote Eb/No

N/A

4 bytes

Query only.
Returns the value of Eb/No of the remote demod.
Responds 99.9 = remote demod unlocked.
Responds xx.x if EDMAC is disabled.
xx.x=02.0 to 16.0

Example: REB=12.4
Note: For values > 16.0 dB, the reply will be 16.0

N/A REB? REB=xx.x

(see description of
arguments)

Tx Power
Level Increase

N/A

3 bytes

Query only.
Returns the increase in Tx power level, in dB (from the nominal
setting) due to the action of AUPC. Range is 0.0 to 9.9 dB
Responds x.x if AUPC is disabled.

Example: PLI=2.3

N/A PLI? PLI=x.x

(see description of
arguments)