Mocomtech CDM-570 User Manual

Page 248

Advertising
background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 4

Serial Remote Control

MN/CDM570L.IOM

13–14

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Rx Data Invert

RDI=

1 byte, value 0
or 1

Command or Query.
Invert Receive Data, where:
0=Normal
1=Inverted

Example: RDI = 1 (selects Inverted Rx Data)

RDI=
RDI?
RDI*
RDI#

RDI?

RDI=x
(see description of
arguments)

Rx Demod
Acquisition
Sweep Width

RSW=

3 bytes

Command or Query.
Rx

± acquisition sweep range of demodulator, in kHz, ranging

from

± 1 to ± 32 kHz (rates < 625 ksym/second)

or

± 1 to ± 200 kHz (rates >= 625 ksym/second) CDM-570L only


Example: RSW=009 (selects

± 9 kHz)

RSW=
RSW?
RSW*
RSW#

RSW?

RSW=xxx
(see description of
arguments)

Eb/No Alarm
Point

EBA=

4 bytes

Command or Query.
Eb/No alarm point in dB, with a range between 0.1 and 16 dB.
Resolution=0.1 dB

Example: EBA=12.3

EBA=
EBA?
EBA*
EBA#

EBA? EBA=xx.x

(see description of
arguments)

Rx Buffer Size

RBS=

1 byte,
value of 0
through 9

Command or Query.
Rx buffer size, where:
0 = Buffer disabled (Clock mode = Rx satellite)
1 = +/- 1024 bits
2 = +/- 2048 bits
3 = +/- 4096 bits
4 = +/- 8192 bits
5 = +/- 16384 bits
6 = +/- 32768 bits
7 = +/- 128 bits
8 = +/- 256 bits
9 = +/- 512 bits
Example: RBS=0

RBS=
RBS?
RBS*
RBS#

RBS? RBS=x

(same format as
command argument)

Advertising