Interface commands, 2 interface commands – Mocomtech CDM-570 User Manual

Page 25

Advertising
background image

Page 15 of 54

MN/CDM570L.AA4

21

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Enable/Disable
QoS Feature

QSE=

1 byte value
0 – Disable
1 – Enable

Command or Query.
Setting this to ‘1’ enables the Quality of Service feature.
Setting to ‘0’ disables it.

QSE=
QSE!

QSE?

QSE=x

System
Configuration
Get

None

String of
Variable byte
size

Query only.
Querying the SCG? Dumps the system configuration. This can be
used for updating the GUI parameters. See the Appendix section
for more information on individual field.

SCG=
SCG!

SCG?

SCG= string of variable
byte size.



3.4.2 Interface Commands

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Ethernet MAC

NONE

12 bytes

Query only.
Returns the Ethernet MAC address, format:

Example: ETM=0006B0000178

ETM!

ETM?

ETM=xxxxxxxxxxxx
(see description of
arguments)

Ether speed
mode

ESM=

1 byte, value
of 1..5

Command or Query.
1 -- Auto
2 -- 10 MB/sec Half Duplex
3 -- 100 MB/sec Half Duplex
4 -- 10 MB/sec Full Duplex
5 -- 100 MB/sec Full Duplex

Specifies the speed and mode of Ethernet interface.

ESM =
ESM!

ESM?

ESM = x
(see description of
arguments)

Advertising