Mocomtech CDM-570 User Manual

Page 253

Advertising
background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 4

Serial Remote Control

MN/CDM570L.IOM

13–19

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Configuration
Save

CST=

1 byte

Command only.
Causes the CDM570L to store the current modem configuration in
Configuration Memory location defined by the one-byte argument
(0 to 9).

Example: CST=4 (store the current configuration in location 4)

CST=
CST?
CST*
CST#

N/A N/A

Configuration
Load

CLD=

1 byte

Command only.
Causes the CDM570L to retrieve a previously stored modem
configuration from Configuration Memory location defined by the
one-byte argument (0 to 9).

Example: CLD=4 (retrieve modem configuration from
location 4)

CLD=
CLD?
CLD*
CLD#

N/A N/A

ReCenter
Buffer

RCB= None

Command

only.

Forces the software to recenter the receive Plesiochronous/Doppler
buffer.
Note: This command takes no arguments.

Example: RCB=

RCB=
RCB?
RCB*
RCB#

N/A N/A

RTC Date

DAY=

6 bytes

Command or Query.
A date in the form ddmmyy, where
dd = day of the month (01 to 31),
mm = month (01 to 12)
yy = year (00 to 99)

Example: DAY=240457 (April 24, 2057)

DAY=
DAY?
DAY*
DAY#

DAY? DAY=ddmmyy

(see description of
arguments)

RTC Time

TIM=

6 bytes

Command or Query.
A time in the form hhmmss, indicating the time from midnight,
where:
hh = hours (00 to 23)
mm = minutes (00 to 59)
ss = seconds (00 to 59)

Example: TIM=231259 (23 hours:12 minutes:59 seconds)

TIM=
TIM?
TIM*
TIM#

TIM? TIM=hhmmss

(see description of
arguments)