Mocomtech CDM-570 User Manual

Page 260

Advertising
background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 4

Serial Remote Control

MN/CDM570L.IOM

13–26

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Faults and
Status

N/A

6 bytes

Query only.

Unit returns the current highest-priority fault and status codes for the Unit

(hardware), Tx Traffic, Rx Traffic and ODU in the form abcdef, where:

a = Unit faults:

0 = No faults

1 = Power supply fault, +5 volts

2 = Power supply fault , +12 volts

3 = Power supply fault, –5 volts

4 = Power supply fault, +23 volts

5 = Power supply fault, –12 volts

6 = Tx synthesizer lock

7 = Rx 1st LO synthesizer lock

8 = Rx 2

nd

LO synthesizer Lock

9 = Ref PLL lock

E = IP Module

F = EEPROM checksum error

A, B, C, and D are TBD (for future expansion)

b = Tx Traffic status:

0 = Tx traffic OK

1 = No clock from terrestrial interface

3 = Tx FIFO slip

5 = Loss of External Reference

7 = AUPC upper limit reached

9 = AIS detected on incoming data

B = Bipolar violation on G.703 interface

2, 4, 6, 8 and A are TBD (for future expansion)

c = Rx Traffic status:

0 = Rx Traffic OK

1 = Demodulator unlocked

3 = AGC Alarm - signal out of range

5 = RS Frame sync alarm

7 = EDMAC Frame sync alarm

A = Buffer Underflow

B = Buffer Overflow

D = Eb/No alarm

F = AIS detected on incoming data

2, 4, 6, 8, 9, C and E are TBD (for future expansion)

d = ODU status:

0=No ODU faults

1=BUC PLL

3=BUC current

5=BUC voltage

7=LNB current

9=LNB voltage

B=BUC temperature

D=BUC checksum

2, 4, 6, 8, A, and C are TBD (for future expansion)

N/A FLT? FLT=abcdef

(see

description for details of
arguments)

e=Change in fault status
since last poll.

f=Change in unit
configuration since last
poll

(see description of
arguments)

Advertising