Mocomtech CDM-570 User Manual

Page 263

Advertising
background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 4

Serial Remote Control

MN/CDM570L.IOM

13–29

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

BUC LO
Frequency

BLO=

6 bytes

Command or Query. CDM-570L Only
BUC transmit LO frequency information in the form: xxxxxs,
where:
xxxxx is the LO frequency, in the range of 3000 to 65000 MHz
All 0’s (000000) disables the feature.
s is the sign for the mix (+ or - character)
Terminal Frequency = BUC LO

± TFQ


Example: BLO = 12000+ (BUC LO is 12 GHz, low-side mix)

BLO=
BLO?
BLO*
BLO#

BLO? BLO=xxxxxs

(see description of
arguments)

BUC Output
Power Level

N/A

4 bytes

Query only. CDM-570L Only
BUC output power level in the form xx.x, where xx.x is the value
in Watts.

Example: BOL=08.3 (BUC reports output power is 8.3 Watts)
Returns 00.0 when FSK and BUC power are not enabled.

N/A BOL? BOL=xx.x

(see description of
arguments)

BUC
Temperature

N/A

3 bytes

Query only. CDM-570L Only
Indicates BUC temperature, in the form: sxx, where:
s = sign (+ or - character)
xx = value
If not available, response is –99

Example: BUT=-13 (BUC temperature is -13 degrees C)
Note: This query is only valid when the FSK and BUC power are
turned On.

N/A BUT? BUT=sxx

(see description of
arguments)

BUC PLL
Alarm

N/A

1 byte, value
of 0 or 1

Query only. CDM-570L Only
BUC PLL lock state, where:
1=Unlocked
0=Locked
Example: BPA=0 (BUC PLL is locked)
If not available, response is 9
Note: This command is only valid when the FSK and BUC power
are turned On.

N/A BPA? BPA=x

(see description of
arguments)

Advertising